Your browser doesn't support javascript.
loading
Primary cerebral lymphoma and glioblastoma multiforme: differences in diffusion characteristics evaluated with diffusion tensor imaging.
Toh, C-H; Castillo, M; Wong, A M-C; Wei, K-C; Wong, H-F; Ng, S-H; Wan, Y-L.
Affiliation
  • Toh CH; Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Tao-Yuan, Taiwan. eldomtoh@hotmail.com
AJNR Am J Neuroradiol ; 29(3): 471-5, 2008 Mar.
Article de En | MEDLINE | ID: mdl-18065516
ABSTRACT
BACKGROUND AND

PURPOSE:

Differentiating between primary cerebral lymphoma and glioblastoma multiforme (GBM) based on conventional MR imaging sequences may be impossible. Our hypothesis was that there are significant differences in fractional anisotropy (FA) and apparent diffusion coefficient (ADC) between lymphoma and GBM, which will allow for differentiation between them. MATERIALS AND

METHODS:

Preoperative diffusion tensor imaging (DTI) was performed in 10 patients with lymphoma and 10 patients with GBM. Regions of interest were placed in only solid-enhancing tumor areas and the contralateral normal-appearing white matter (NAWM) to measure the FA and ADC values. The differences in FA and ADC between lymphoma and GBM, as well as between solid-enhancing areas of each tumor type and contralateral NAWM, were analyzed statistically. Cutoff values of FA, FA ratio, ADC, and ADC ratio for distinguishing lymphomas from GBMs were determined by receiver operating characteristic curve analysis.

RESULTS:

FA and ADC values of lymphoma were significantly decreased compared with NAWM. Mean FA, FA ratio, ADC (x10(-3) mm(2)/s), and ADC ratios were 0.140 +/- 0.024, 0.25 +/- 0.04, 0.630 +/- 0.155, and 0.83 +/- 0.14 for lymphoma, respectively, and 0.229 +/- 0.069, 0.40 +/- 0.12, 0.963 +/- 0.119, and 1.26 +/- 0.13 for GBM, respectively. All of the values were significantly different between lymphomas and GBM. Cutoff values to differentiate lymphomas from GBM were 0.192 for FA, 0.33 for FA ratio, 0.818 for ADC, and 1.06 for ADC ratio.

CONCLUSIONS:

The FA and ADC of primary cerebral lymphoma were significantly lower than those of GBM. DTI is able to differentiate lymphomas from GBM.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Encéphale / Tumeurs du cerveau / Interprétation d'images assistée par ordinateur / Glioblastome / Imagerie par résonance magnétique de diffusion / Lymphomes Type d'étude: Diagnostic_studies / Evaluation_studies Limites: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Langue: En Journal: AJNR Am J Neuroradiol Année: 2008 Type de document: Article Pays d'affiliation: Taïwan

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Encéphale / Tumeurs du cerveau / Interprétation d'images assistée par ordinateur / Glioblastome / Imagerie par résonance magnétique de diffusion / Lymphomes Type d'étude: Diagnostic_studies / Evaluation_studies Limites: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Langue: En Journal: AJNR Am J Neuroradiol Année: 2008 Type de document: Article Pays d'affiliation: Taïwan