Your browser doesn't support javascript.
loading
Photon irradiation response of photonic crystal fibres and flat fibres at radiation therapy doses.
Hashim, S; Ibrahim, S A; Che Omar, S S; Alajerami, Y S M; Saripan, M I; Noor, N M; Ung, N M; Mahdiraji, G A; Bradley, D A; Alzimami, K.
Affiliation
  • Hashim S; Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia; Oncology Treatment Centre, Sultan Ismail Hospital, 81100 Johor Bahru, Malaysia. Electronic address: suhairul@utm.my.
  • Ibrahim SA; Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
  • Che Omar SS; Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
  • Alajerami YS; Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia.
  • Saripan MI; FRG Biomedical Engineering, Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia.
  • Noor NM; Faculty of Medicine and Health Sciences Universiti Putra Malaysia, 43400 Serdang, Selangor, Malaysia.
  • Ung NM; Clinical Oncology Unit, Faculty of Medicine, University of Malaya, 50603 Kuala Lumpur, Malaysia.
  • Mahdiraji GA; Department of Electrical Engineering, Faculty of Engineering Building, University of Malaya, 50603 Kuala Lumpur, Malaysia.
  • Bradley DA; Department of Physics, University of Surrey, Guildford GU2 7XH, U.K; Department of Physics, Universiti Malaya, 50603 Kuala Lumpur, Malaysia.
  • Alzimami K; Department of Radiological Sciences, Applied Medical Sciences College, King Saud University, P.O. Box 10219, Riyadh 11433, Saudi Arabia.
Appl Radiat Isot ; 90: 258-60, 2014 Aug.
Article de En | MEDLINE | ID: mdl-24858954
ABSTRACT
Radiation effects of photon irradiation in pure Photonic Crystal Fibres (PCF) and Flat fibres (FF) are still much less investigated in thermoluminescense dosimetry (TLD). We have reported the TL response of PCF and FF subjected to 6 MV photon irradiation. The proposed dosimeter shows good linearity at doses ranging from 1 to 4 Gy. The small size of these detectors points to its use as a dosimeter at megavoltage energies, where better tissue-equivalence and the Bragg-Gray cavity theory prevails.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Dose de rayonnement / Dosimétrie par thermoluminescence / Photons / Silice / Fibres optiques Langue: En Journal: Appl Radiat Isot Sujet du journal: MEDICINA NUCLEAR / SAUDE AMBIENTAL Année: 2014 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Dose de rayonnement / Dosimétrie par thermoluminescence / Photons / Silice / Fibres optiques Langue: En Journal: Appl Radiat Isot Sujet du journal: MEDICINA NUCLEAR / SAUDE AMBIENTAL Année: 2014 Type de document: Article