Your browser doesn't support javascript.
loading
A numerical model to reproduce squeaking of ceramic-on-ceramic total hip arthroplasty. Influence of design and material.
Piriou, P; Ouenzerfi, G; Migaud, H; Renault, E; Massi, F; Serrault, M.
Affiliation
  • Piriou P; Clinique du parc, 6, avenue du Morvan, 71400 Autun, France.
  • Ouenzerfi G; Institut National des Sciences Appliquées de Lyon (INSA), Laboratoire de Mécanique des Contacts et des Structures, bâtiment Jean-d'Alembert, 18-20, rue des Sciences, 69621 Villeurbanne cedex, France.
  • Migaud H; Université de Lille, Département Universitaire de Chirurgie Orthopédique et de Traumatologie, place de Verdun, 59000 Lille, France. Electronic address: hemigaud@nordnet.fr.
  • Renault E; Tornier, 161, rue Lavoisier, 38334 Montbonnot, France.
  • Massi F; Institut National des Sciences Appliquées de Lyon (INSA), Laboratoire de Mécanique des Contacts et des Structures, bâtiment Jean-d'Alembert, 18-20, rue des Sciences, 69621 Villeurbanne cedex, France.
  • Serrault M; Clinique Saint-Dominique, 99, rue de Messei, 61100 Flers, France.
Orthop Traumatol Surg Res ; 102(4 Suppl): S229-34, 2016 06.
Article de En | MEDLINE | ID: mdl-27033843
ABSTRACT

BACKGROUND:

Modern ceramic (CoC) bearings for hip arthroplasty (THA) have been used in younger patients who expect improved survivorship. However, audible squeaking produced by the implant is an annoying complication. Previous numerical simulations were not able to accurately reproduce in vitro and in vivo observations. Therefore, we developed a finite element model to (1) reproduce in vitro squeaking and validate the model by comparing it with in vivo recordings, (2) determine why there are differences between in vivo and in vitro squeaking frequencies, (3) identify the stem's role in this squeaking, (4) predict which designs and materials are more likely to produce squeaking.

HYPOTHESIS:

A CoC THA numerical model can be developed that reproduces the squeaking frequencies observed in vivo. MATERIAL AND

METHODS:

Numerical methods (finite element analysis [ANSYS]) and experimental methods (using a non-lubricated simulated hip with a cementless 32mm CoC THA) were developed to reproduce squeaking. Numerical analysis was performed to identify the frequencies that cause vibrations perceived as an acoustic emission. The finite element analysis (FEA) model was enhanced by adjusting periprosthetic bone and soft tissue elements in order to reproduce the squeaking frequencies recorded in vivo. A numerical method (complex eigenvalue analysis) was used to find the acoustic frequencies of the squeaking noise. The frequencies obtained from the model and the hip simulator were compared to those recorded in vivo.

RESULTS:

The numerical results were validated by experiments with the laboratory hip simulator. The frequencies obtained (mean 2790Hz with FEA, 2755Hz with simulator, decreasing to 1759Hz when bone and soft tissue were included in the FEA) were consistent with those of squeaking hips recorded in vivo (1521Hz). The cup and ceramic insert were the source of the vibration, but had little influence on the diffusion of the noise required to make the squeaking audible to the human ear. The FEA showed that diffusion of squeaking was due to an unstable vibration of the stem during frictional contact. The FEA predicted a higher rate of squeaking (at a lower coefficient of friction) when TZMF™ alloy is used instead of Ti6Al4V and when an anatomic press-fit stem is used instead of straight self-locking designs.

DISCUSSION:

The current FEA model is reliable; it can be used to assess various stem designs and alloys to predict the different rates of squeaking that certain stems will likely produce. LEVEL OF EVIDENCE Level IV in vitro study.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Conception de prothèse / Céramiques / Arthroplastie prothétique de hanche / Prothèse de hanche / Modèles théoriques / Bruit Type d'étude: Prognostic_studies Limites: Humans Langue: En Journal: Orthop Traumatol Surg Res Année: 2016 Type de document: Article Pays d'affiliation: France

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Conception de prothèse / Céramiques / Arthroplastie prothétique de hanche / Prothèse de hanche / Modèles théoriques / Bruit Type d'étude: Prognostic_studies Limites: Humans Langue: En Journal: Orthop Traumatol Surg Res Année: 2016 Type de document: Article Pays d'affiliation: France