Ultrathin disposable gastroscope for screening and surveillance of gastroesophageal varices in patients with liver cirrhosis: a prospective comparative study.
Huynh, Dep K; Toscano, Leanne; Phan, Vinh-An; Ow, Tsai-Wing; Schoeman, Mark; Nguyen, Nam Q.
Affiliation
  • Huynh DK; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Discipline of Medicine, University of Adelaide, Adelaide, South Australia, Australia.
  • Toscano L; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia.
  • Phan VA; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Discipline of Medicine, University of Adelaide, Adelaide, South Australia, Australia.
  • Ow TW; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia.
  • Schoeman M; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia.
  • Nguyen NQ; Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Adelaide, South Australia, Australia; Discipline of Medicine, University of Adelaide, Adelaide, South Australia, Australia.
Gastrointest Endosc ; 85(6): 1212-1217, 2017 Jun.
Article de En | MEDLINE | ID: mdl-27894929
ABSTRACT
BACKGROUND AND

AIMS:

This study aims to evaluate the role of unsedated, ultrathin disposable gastroscopy (TDG) against conventional gastroscopy (CG) in the screening and surveillance of gastroesophageal varices (GEVs) in patients with liver cirrhosis.

METHOD:

Forty-eight patients (56.4 ± 1.3 years; 38 male, 10 female) with liver cirrhosis referred for screening (n = 12) or surveillance (n = 36) of GEVs were prospectively enrolled. Unsedated gastroscopy was initially performed with TDG, followed by CG with conscious sedation. The 2 gastroscopies were performed by different endoscopists blinded to the results of the previous examination. Video recordings of both gastroscopies were validated by an independent investigator in a random, blinded fashion. Endpoints were accuracy and interobserver agreement of detecting GEVs, safety, and potential cost saving.

RESULTS:

CG identified GEVs in 26 (54%) patients, 10 of whom (21%) had high-risk esophageal varices (HREV). Compared with CG, TDG had an accuracy of 92% for the detection of all GEVs, which increased to 100% for high-risk GEVs. The interobserver agreement for detecting all GEVs on TDG was 88% (κ = 0.74). This increased to 94% (κ = 0.82) for high-risk GEVs. There were no serious adverse events.

CONCLUSIONS:

Unsedated TDG is safe and has high diagnostic accuracy and interobserver reliability for the detection of GEVs. The use of clinic-based TDG would allow immediate determination of a follow-up plan, making it attractive for variceal screening and surveillance programs. (Clinical trial (ANZCTR) registration number ACTRN12616001103459.).
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Varices oesophagiennes et gastriques / Gastroscopes / Matériel jetable / Conception d'appareillage Type d'étude: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limites: Female / Humans / Male / Middle aged Langue: En Journal: Gastrointest Endosc Année: 2017 Type de document: Article Pays d'affiliation: Australie

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Varices oesophagiennes et gastriques / Gastroscopes / Matériel jetable / Conception d'appareillage Type d'étude: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limites: Female / Humans / Male / Middle aged Langue: En Journal: Gastrointest Endosc Année: 2017 Type de document: Article Pays d'affiliation: Australie