Simultaneous validation of five activity monitors for use in adult populations.
Powell, C; Carson, B P; Dowd, K P; Donnelly, A E.
Affiliation
  • Powell C; Department of Physical Education and Sport Sciences, Centre for Physical Activity and Health Research, University of Limerick, Limerick, Ireland.
  • Carson BP; Department of Physical Education and Sport Sciences, Centre for Physical Activity and Health Research, University of Limerick, Limerick, Ireland.
  • Dowd KP; Health Research Institute, University of Limerick, Limerick, Ireland.
  • Donnelly AE; Department of Sport and Health, Faculty of Science, Athlone Institute of Technology, Athlone, Westmeath, Ireland.
Scand J Med Sci Sports ; 27(12): 1881-1892, 2017 Dec.
Article de En | MEDLINE | ID: mdl-27905148
ABSTRACT
Numerous cut-points exist to measure physical activity by accelerometry. The ability to compare accelerometer findings from different devices from different locations may be advantageous to researchers. This study aimed to develop and validate cut-points for 1.5, 3, and 6 METs in five activity monitors simultaneously. Fifty-six participants (mean age=39.9 [±11.5] years) performed six activities while wearing a CosMED K4b2 and five activity monitors activPAL3 Micro, activPAL, ActiGraph GT1M, ActiGraph wGT3X-BT, and GENEActiv. Receiver operating characteristic curves and analysis were used to develop and validate cut-points for the vertical axis counts (all activity monitors) and sum of the vector magnitude (ActiGraph wGT3X-BT and GENEActiv) for 15 second (all devices) and 60 second (ActiGraph devices) epochs. A random coefficients statistical model was used to derive MET predictive equations for all activity monitors. Bland-Altman plots examined the variability in device error. No 1.5 MET cut-points were developed for the activPAL devices. All developed cut-points had high levels of sensitivity and specificity. When cross-validated in an independent group, high levels of sensitivity and specificity remained (≥77.4%, monitor and intensity dependent). The mean bias based on the Bland-Altman plots ranged from -0.03 METs to 0.35 METs (monitor dependent). This is the first study to develop and validate cut-points for five activity monitors simultaneously with high levels of sensitivity and specificity (≥77.4%). This is potentially a step toward cross-comparison/harmonization of data; however, further validation in a free-living environment is warranted.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Actigraphie / Moniteurs de condition physique Type d'étude: Diagnostic_studies / Prognostic_studies Limites: Adult / Humans / Male / Middle aged Langue: En Journal: Scand J Med Sci Sports Sujet du journal: MEDICINA ESPORTIVA Année: 2017 Type de document: Article Pays d'affiliation: Irlande

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Actigraphie / Moniteurs de condition physique Type d'étude: Diagnostic_studies / Prognostic_studies Limites: Adult / Humans / Male / Middle aged Langue: En Journal: Scand J Med Sci Sports Sujet du journal: MEDICINA ESPORTIVA Année: 2017 Type de document: Article Pays d'affiliation: Irlande