Your browser doesn't support javascript.
loading
Development and Application of an MSALL-Based Approach for the Quantitative Analysis of Linear Polyethylene Glycols in Rat Plasma by Liquid Chromatography Triple-Quadrupole/Time-of-Flight Mass Spectrometry.
Zhou, Xiaotong; Meng, Xiangjun; Cheng, Longmei; Su, Chong; Sun, Yantong; Sun, Lingxia; Tang, Zhaohui; Fawcett, John Paul; Yang, Yan; Gu, Jingkai.
Affiliation
  • Zhou X; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
  • Meng X; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
  • Cheng L; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
  • Su C; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
  • Sun Y; School of Pharmaceutical Sciences, Jilin University , Changchun 130012, PR China.
  • Sun L; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
  • Tang Z; Key Laboratory of Polymer Ecomaterials, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences , Changchun, 130022, PR China.
  • Fawcett JP; School of Pharmacy, University of Otago , Dunedin, P.O. Box 56, New Zealand.
  • Yang Y; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
  • Gu J; School of Life Sciences, Jilin University , Changchun, 130012, PR China.
Anal Chem ; 89(10): 5193-5200, 2017 05 16.
Article de En | MEDLINE | ID: mdl-28418637
ABSTRACT
Polyethylene glycols (PEGs) are synthetic polymers composed of repeating ethylene oxide subunits. They display excellent biocompatibility and are widely used as pharmaceutical excipients. To fully understand the biological fate of PEGs requires accurate and sensitive analytical methods for their quantitation. Application of conventional liquid chromatography-tandem mass spectrometry (LC-MS/MS) is difficult because PEGs have polydisperse molecular weights (MWs) and tend to produce multicharged ions in-source resulting in innumerable precursor ions. As a result, multiple reaction monitoring (MRM) fails to scan all ion pairs so that information on the fate of unselected ions is missed. This Article addresses this problem by application of liquid chromatography-triple-quadrupole/time-of-flight mass spectrometry (LC-Q-TOF MS) based on the MSALL technique. This technique performs information-independent acquisition by allowing all PEG precursor ions to enter the collision cell (Q2). In-quadrupole collision-induced dissociation (CID) in Q2 then effectively generates several fragments from all PEGs due to the high collision energy (CE). A particular PEG product ion (m/z 133.08592) was found to be common to all linear PEGs and allowed their total quantitation in rat plasma with high sensitivity, excellent linearity and reproducibility. Assay validation showed the method was linear for all linear PEGs over the concentration range 0.05-5.0 µg/mL. The assay was successfully applied to the pharmacokinetic study in rat involving intravenous administration of linear PEG 600, PEG 4000, and PEG 20000. It is anticipated the method will have wide ranging applications and stimulate the development of assays for other pharmaceutical polymers in the future.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Polyéthylène glycols / Spectrométrie de masse en tandem Limites: Animals Langue: En Journal: Anal Chem Année: 2017 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Polyéthylène glycols / Spectrométrie de masse en tandem Limites: Animals Langue: En Journal: Anal Chem Année: 2017 Type de document: Article