Your browser doesn't support javascript.
loading
Optimisation of extraction methods and quantification of benzo[a]pyrene and benz[a]anthracene in yerba maté tea by isotope dilution mass spectrometry.
Gui, Ee Mei; Lu, Ting; Teo, Tang Lin; Cheow, Pui Sze; Lee, Tong Kooi.
Affiliation
  • Gui EM; Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
  • Lu T; Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
  • Teo TL; Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore. Teo_Tang_Lin@hsa.gov.sg.
  • Cheow PS; Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
  • Lee TK; Chemical Metrology Laboratory, Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 1 Science Park Road, #01-05/06, The Capricorn, Singapore Science Park II, Singapore, 117528, Singapore.
Anal Bioanal Chem ; 409(26): 6069-6080, 2017 Oct.
Article de En | MEDLINE | ID: mdl-28808779
ABSTRACT
A gas chromatography-isotope dilution mass spectrometry (GC-IDMS) technique was developed for the quantification of two heavy polyaromatic hydrocarbons (PAHs), benz[a]anthracene and benzo[a]pyrene, in yerba maté tea (maté). The optimisation of two extraction methods, namely liquid-liquid extraction and accelerated solvent extraction, was carried out. Both optimised methods were validated using a certified reference material of fine dust and the results were within the expanded uncertainties at 95% confidence level. Recoveries of 99.2-106.7% with RSD of measurements of 1.1-2.3% were achieved for benz[a]anthracene. Recoveries of 95.7-101.9% with RSD of measurements of 0.4-1.4% were achieved for benzo[a]pyrene. The validated methods were applied for the extraction of benz[a]anthracene and benzo[a]pyrene in maté powder from NIST. A metrological approach was undertaken to ensure the traceability of measurement results. The uncertainties associated with the results were rigorously evaluated and also reported herein. Graphical abstract Quantification of benz[a]anthracene and benzo[a]pyrene using IDMS.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Spectrométrie de masse / Benzo[a]anthracènes / Benzo[a]pyrène / Ilex paraguariensis / Extraction liquide-liquide / Tisanes Langue: En Journal: Anal Bioanal Chem Année: 2017 Type de document: Article Pays d'affiliation: Singapour

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Spectrométrie de masse / Benzo[a]anthracènes / Benzo[a]pyrène / Ilex paraguariensis / Extraction liquide-liquide / Tisanes Langue: En Journal: Anal Bioanal Chem Année: 2017 Type de document: Article Pays d'affiliation: Singapour
...