Clinical and laboratory factors contributing to uninterpretable beryllium lymphocyte proliferation tests (BeLPT).
Am J Ind Med
; 61(7): 592-604, 2018 07.
Article
de En
| MEDLINE
| ID: mdl-29574954
ABSTRACT
BACKGROUND:
The beryllium lymphocyte proliferation test (BeLPT), has become the principal clinical test for detecting beryllium sensitization and chronic beryllium disease. Uninterpretable BeLPT results can occur in a small but significant proportion of tests from poor lymphocyte growth (PG) or over proliferation of lymphocytes (OP). The clinical and laboratory causes of uninterpretable results are not known.METHODS:
BeLPT data from the US Department of Energy-supported Former Worker Screening Program were analyzed for a 10-year period. Drivers of uninterpretable BeLPTs were investigated using multivariable models and classification techniques.RESULTS:
Three participant attributes were significantly associated with PG, while OP showed no significant associations. Serum lot for the lymphocyte growth medium accounted for 21% of the variation in PG and 16% in OP.CONCLUSION:
Serum lots influence the likelihood of having uninterpretable BeLPT. To better understand uninterpretable results and possibly reduce their occurrence, additional laboratory-related factors should be addressed.Mots clés
Texte intégral:
1
Collection:
01-internacional
Base de données:
MEDLINE
Sujet principal:
Bérylliose
/
Béryllium
/
Lymphocytes
/
Techniques de laboratoire clinique
/
Prolifération cellulaire
Type d'étude:
Diagnostic_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/