Your browser doesn't support javascript.
loading
Endoscopist biopsy rate as a quality indicator for outpatient gastroscopy: a multicenter cohort study with validation.
Januszewicz, Wladyslaw; Wieszczy, Paulina; Bialek, Andrzej; Karpinska, Katarzyna; Szlak, Jakub; Szymonik, Jakub; Rupinski, Maciej; Mroz, Andrzej; Regula, Jaroslaw; Kaminski, Michal F.
Affiliation
  • Januszewicz W; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Centre for Postgraduate Education, Warsaw, Poland; MRC Cancer Unit, University of Cambrid
  • Wieszczy P; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Centre for Postgraduate Education, Warsaw, Poland; Department of Cancer Prevention, The Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw, Poland.
  • Bialek A; Department of Gastroenterology, Pomeranian Medical University, Szczecin, Poland.
  • Karpinska K; Department of Pathomorphology, Pomeranian Medical University, Szczecin, Poland.
  • Szlak J; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland.
  • Szymonik J; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland.
  • Rupinski M; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Centre for Postgraduate Education, Warsaw, Poland.
  • Mroz A; Department of Pathomorphology, Medical Centre for Postgraduate Education, Warsaw, Poland; Department of Pathology and Laboratory Medicine, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland.
  • Regula J; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Centre for Postgraduate Education, Warsaw, Poland.
  • Kaminski MF; Department of Gastroenterological Oncology, The Maria Sklodowska-Curie Memorial Cancer Centre and Institute of Oncology, Warsaw, Poland; Department of Gastroenterology, Hepatology and Clinical Oncology, Medical Centre for Postgraduate Education, Warsaw, Poland; Department of Cancer Prevention, The M
Gastrointest Endosc ; 89(6): 1141-1149, 2019 06.
Article de En | MEDLINE | ID: mdl-30659831
BACKGROUND AND AIMS: The diagnosis of gastric premalignant conditions (GPCs) relies on endoscopy with mucosal sampling. We hypothesized that the endoscopist biopsy rate (EBR) might constitute a quality indicator for EGD, and we have analyzed its association with GPC detection and the rate of missed gastric cancers (GCs). METHODS: We analyzed EGD databases from 2 high-volume outpatient units. EBR values, defined as the proportion of EGDs with ≥1 biopsy to all examinations were calculated for each endoscopist in Unit A (derivation cohort) and divided by the quartile values into 4 groups. Detection of GPC was calculated for each group and compared using multivariate clustered logistic regression models. Unit B database was used for validation. All patients were followed in the Cancer Registry for missed GCs diagnosed between 1 month and 3 years after EGDs with negative results. RESULTS: Sixteen endoscopists in Unit A performed 17,490 EGDs of which 15,340 (87.7%) were analyzed. EBR quartile values were 22.4% to 36.7% (low EBR), 36.8% to 43.7% (moderate), 43.8% to 51.6% (high), and 51.7% and 65.8% (very-high); median value 43.8%. The odds ratios for the moderate, high, and very-high EBR groups of detecting GPC were 1.6 (95% confidence interval [CI], 1.3-1.9), 2.0 (95% CI, 1.7-2.4), and 2.5 (95% CI, 2.1-2.9), respectively, compared with the low EBR group (P < .001). This association was confirmed with the same thresholds in the validation cohort. Endoscopists with higher EBR (≥43.8%) had a lower risk of missed cancer compared with those in the lower EBR group (odds ratio, 0.44; 95% CI, 0.20-1.00; P = .049). CONCLUSIONS: The EBR parameter is highly variable among endoscopists and is associated with efficacy in GPC detection and the rate of missed GCs.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: États précancéreux / Tumeurs de l'estomac / Biopsie / Gastroscopie / Indicateurs qualité santé / Gastrite atrophique Type d'étude: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limites: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Pays/Région comme sujet: Europa Langue: En Journal: Gastrointest Endosc Année: 2019 Type de document: Article Pays de publication: États-Unis d'Amérique

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: États précancéreux / Tumeurs de l'estomac / Biopsie / Gastroscopie / Indicateurs qualité santé / Gastrite atrophique Type d'étude: Diagnostic_studies / Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limites: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Pays/Région comme sujet: Europa Langue: En Journal: Gastrointest Endosc Année: 2019 Type de document: Article Pays de publication: États-Unis d'Amérique