Ultrasound-guided greater occipital nerve block with botulinum toxin for patients with chronic headache in the occipital area: a randomized controlled trial.
Ryu, Jae Hyung; Shim, Jae Hang; Yeom, Jong Hoon; Shin, Woo Jong; Cho, Sang Yun; Jeon, Woo Jae.
Affiliation
  • Ryu JH; Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
  • Shim JH; Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
  • Yeom JH; Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
  • Shin WJ; Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
  • Cho SY; Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
  • Jeon WJ; Department of Anesthesiology and Pain Medicine, Guri Hospital, Hanyang University College of Medicine, Guri, Korea.
Korean J Anesthesiol ; 72(5): 479-485, 2019 11.
Article de En | MEDLINE | ID: mdl-31159537
ABSTRACT

BACKGROUND:

Ultrasound-guided greater occipital nerve (GON) block has been frequently used to treat various types of headaches, and botulinum toxin has recently begun to be used in patients with headache. Our study presents the long-term effect of botulinum toxin on GON block using ultrasound in patients with chronic headache in occipital area.

METHODS:

Patients with occipital headache were divided into two groups (bupivacaine BUP group [n = 27], botulinum toxin BTX group [n = 27]), and ultrasound-guided GON block was performed at the C2 level. GON was detected with ultrasound and distance from GON to midline, from the skin surface to GON, and size of GON were measured in both groups. Visual analogue scale (VAS) scores and Likert scale were assessed at pretreatment and at 1, 4, 8, and 24 weeks after treatment in both groups.

RESULTS:

The distance from GON to midline was 18.9 ± 4.4 mm (right) and 17.3 ± 3.8 mm (left). The depth from the skin was 12.9 ± 1.5 mm (right) and 13.4 ± 1.6 mm (left). GON size was 3.1 mm on both sides. The VAS score and patient satisfaction score (Likert scale) in 4, 8, and 24 weeks after injection were superior for the BTX than the BUP group.

CONCLUSIONS:

Ultrasound-guided GON block using BTX is effective in reducing short-term and long-term pain in patients with chronic headache in the occipital area.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Bupivacaïne / Toxines botuliniques de type A / Céphalées / Bloc nerveux Type d'étude: Clinical_trials Limites: Adult / Aged / Female / Humans / Male / Middle aged Langue: En Journal: Korean J Anesthesiol Année: 2019 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Bupivacaïne / Toxines botuliniques de type A / Céphalées / Bloc nerveux Type d'étude: Clinical_trials Limites: Adult / Aged / Female / Humans / Male / Middle aged Langue: En Journal: Korean J Anesthesiol Année: 2019 Type de document: Article
...