Your browser doesn't support javascript.
loading
Universal and Ultrasensitive Immunochromatographic Assay by Using an Antigen as a Bifunctional Element and Antialbumin Antibody on a Test Line.
Qie, Zhiwei; Liu, Qiqi; Yan, Wenliang; Gao, Zichen; Meng, Wu; Xiao, Rui; Wang, Shengqi.
Affiliation
  • Qie Z; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
  • Liu Q; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
  • Yan W; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
  • Gao Z; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
  • Meng W; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
  • Xiao R; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
  • Wang S; Beijing Institute of Radiation Medicine , Beijing 100850 , People's Republic of China.
Anal Chem ; 91(15): 9530-9537, 2019 08 06.
Article de En | MEDLINE | ID: mdl-31282654
ABSTRACT
A universal and ultrasensitive immunochromatographic assay (ICA) was established using antigen as a bifunctional element and antialbumin antibody in a test line. Preincubation was introduced for competitive recognition. After optimization, the linear detection of aflatoxin M1 (AFM1) with quantum dot bead (QB)-based ICA (QB-ICA) sensor ranged from 10 to 52 pg mL-1, with a 50% inhibitory concentration (IC50) of 23 pg mL-1, which was nearly 49.6-fold lower than those of ICA on a traditional structure with traditional pretreatment (IC50 = 1.10 ng mL-1) and 10-fold lower than those of ICA on a traditional structure with acid aid pretreatment (IC50 = 0.25 ng mL-1). The limit of detection (LOD) for AFM1 was 16 pg mL-1 in milk, which was approximately 16.3-fold times higher than those of ICA on a traditional structure with traditional pretreatment and 6.3-fold higher than those of ICA on a traditional structure with acid aid pretreatment. The LOD improved by 20-fold by using the proposed structure compared to that of conventional enzyme-linked immunosorbent assay (ELISA) for AFM1-spiked milk samples (IC10 = 0.12 ng mL-1). The performance and practicability of the established QB-ICA sensor were validated with a commercial ELISA kit. To evaluate universality, we successfully detected chloramphenicol, with IC50 of 0.42 ng mL-1. Given its high sensitivity and universality, the proposed QB-ICA can be used as an alternative for rapid, sensitive, and universal quantitative detection of all small-molecule analytes.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Dosage immunologique / Aflatoxine M1 / Lait / Albumines / Anticorps / Antigènes Type d'étude: Diagnostic_studies Limites: Animals Langue: En Journal: Anal Chem Année: 2019 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Dosage immunologique / Aflatoxine M1 / Lait / Albumines / Anticorps / Antigènes Type d'étude: Diagnostic_studies Limites: Animals Langue: En Journal: Anal Chem Année: 2019 Type de document: Article
...