Your browser doesn't support javascript.
loading
Study on the effectiveness and safety of Foldable Capsular Vitreous Body implantation.
Zhang, Xiangyang; Tian, Xuemin; Zhang, Baike; Guo, Lisa; Li, Xiaodan; Jia, Yong.
Affiliation
  • Zhang X; Xinxiang Medical University, Xinxiang, 453003, Henan Province, China.
  • Tian X; The People's Liberation Army 988th Hospital (formerly the People's Liberation Army 153rd Hospital), No. 602 Zhengshang Road, Zhengzhou, 450000, Henan Province, China.
  • Zhang B; The People's Liberation Army 988th Hospital (formerly the People's Liberation Army 153rd Hospital), No. 602 Zhengshang Road, Zhengzhou, 450000, Henan Province, China. 13949005500@163.com.
  • Guo L; The People's Liberation Army 988th Hospital (formerly the People's Liberation Army 153rd Hospital), No. 602 Zhengshang Road, Zhengzhou, 450000, Henan Province, China.
  • Li X; The People's Liberation Army 988th Hospital (formerly the People's Liberation Army 153rd Hospital), No. 602 Zhengshang Road, Zhengzhou, 450000, Henan Province, China.
  • Jia Y; The People's Liberation Army 988th Hospital (formerly the People's Liberation Army 153rd Hospital), No. 602 Zhengshang Road, Zhengzhou, 450000, Henan Province, China.
BMC Ophthalmol ; 19(1): 260, 2019 Dec 18.
Article de En | MEDLINE | ID: mdl-31852464
ABSTRACT

BACKGROUND:

Foldable capsular vitreous body (FCVB) was designed to treat severe retinal detachment. The aim of this study was to evaluate the efficacy and safety of the implantation of foldable capsular vitreous body in 1-year follow-up.

METHODS:

A retrospective analysis was conducted for 20 patients with severe ocular trauma or silicone oil (SO) dependent eyes underwent vitrectomy and FCVB implantation in a 1-year follow-up. All treated eyes were peformed clinical examinations involved the visual acuity (VA) examination, Goldmann applanation tonometer, noncontact specular microscopy, fundus photography, B-Scan examination and optical coherence tomography (OCT). The groups were compared with t-test and the McNemar - Bowker test.

RESULTS:

In 1-year follow-up, 20 eyes were evaluated in the study. FCVB well supported the vitreous retina in all treated eyes, and 6 treated eyes achieved retinal reattachment 12 months after FCVB implantation. There were no significant differences in VA before and after FCVB implantation (P = 1.000). In addition, the postoperative IOP markedly elevated from the preoperative IOP of 12.90 ± 7.06 mmHg to 15.15 ± 3.36 mmHg (P = 0.000017). The intraocular pressure (IOP) of 10 eyes maintained at a normal level after surgeries. The other 10 eyes showed slightly lower IOP within the acceptable level. Though two patients developed keratopathy and ocular inflammation respectively, other treated eyes were symmetric with fellow eyes showing satisfactory appearance. Moreover, there was no SO emulsification or leakage happened in the observation.

CONCLUSIONS:

FCVB implantation was an effective and safe treatment in the eyes with severe retinal detachment.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Prothèses et implants / Rétine / Corps vitré / Décollement de la rétine / Lésions traumatiques de l'oeil / Implantation de prothèse Type d'étude: Observational_studies / Prognostic_studies Limites: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged Langue: En Journal: BMC Ophthalmol Sujet du journal: OFTALMOLOGIA Année: 2019 Type de document: Article Pays d'affiliation: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Prothèses et implants / Rétine / Corps vitré / Décollement de la rétine / Lésions traumatiques de l'oeil / Implantation de prothèse Type d'étude: Observational_studies / Prognostic_studies Limites: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged Langue: En Journal: BMC Ophthalmol Sujet du journal: OFTALMOLOGIA Année: 2019 Type de document: Article Pays d'affiliation: Chine