Your browser doesn't support javascript.
loading
An enzyme-free immunosensor for sensitive determination of procalcitonin using NiFe PBA nanocubes@TB as the sensing matrix.
Gao, Zengqiang; Li, Yueyun; Zhang, Chunyan; Zhang, Shuan; Jia, Yilei; Dong, Yunhui.
Affiliation
  • Gao Z; School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, PR China.
  • Li Y; School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, PR China. Electronic address: iyueyun71@163.com.
  • Zhang C; School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, PR China.
  • Zhang S; School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, PR China.
  • Jia Y; School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, PR China.
  • Dong Y; School of Chemistry and Chemical Engineering, Shandong University of Technology, Zibo, 255049, PR China.
Anal Chim Acta ; 1097: 169-175, 2020 Feb 08.
Article de En | MEDLINE | ID: mdl-31910957
ABSTRACT
In this work, a label-free electrochemical immunosensor was developed for the detection of procalcitonin (PCT), using toluidine blue functionalized NiFe Prussian-blue analog nanocubes (NiFe PBA nanocubes@TB) as a signal amplifier. NiFe PBA nanocubes was synthesized by a simple and efficient self-templating method in this work. NiFe PBA nanocubes with open-framework construction not only provides a larger specific area to load a mass of antibodies but produces an excellent signal without adding extra reaction reagent. Besides, the electrochemical performance of NiFe PBA nanocubes can be enhanced after functionalized with TB. The developed immunosensor exhibited favorable performance for PCT detection with a linear range from 0.001 to 25 ng mL-1 and a detection limit of 3 × 10-4 ng mL-1. Moreover, the immunosensor with acceptable reproducibility, selectivity, and stability may provide a new strategy in the clinical detection of PCT.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Chlorure de tolonium / Dosage immunologique / Nanocomposites / Hexacyanoferrates II / Procalcitonine / Fer / Nickel Type d'étude: Diagnostic_studies Limites: Humans Langue: En Journal: Anal Chim Acta Année: 2020 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Chlorure de tolonium / Dosage immunologique / Nanocomposites / Hexacyanoferrates II / Procalcitonine / Fer / Nickel Type d'étude: Diagnostic_studies Limites: Humans Langue: En Journal: Anal Chim Acta Année: 2020 Type de document: Article