Your browser doesn't support javascript.
loading
Validation of 4-meter-gait-speed test and 5-repetitions-sit-to-stand test in patients with pulmonary fibrosis: a clinimetric validation study.
Bloem, Ada E M; Veltkamp, Marcel; Spruit, Martijn A; Custers, Jan W H; Bakker, Eric W P; Dolk, Hanneke M; Grutters, Jan C.
Affiliation
  • Bloem AEM; University of Applied Sciences Utrecht, Institute of Movement Studies, Faculty of Health Care, Utrecht, The Netherlands.
  • Veltkamp M; Interstitial Lung Diseases Center of Excellence, Department of Pulmonology, St Antonius Hospital, Nieuwegein, The Netherlands.
  • Spruit MA; Division of Heart and Lungs, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Custers JWH; Department of Research and Education, CIRO+, Center of Expertise for Chronic Organ Failure, Horn, The Netherlands.
  • Bakker EWP; Department of Respiratory Medicine, Maastricht University Medical Center, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht, The Netherlands.
  • Dolk HM; REVAL - Rehabilitation Research Center, BIOMED - Biomedical Research Institute, Faculty of Medicine and Life Sciences, Hasselt University, Diepenbeek, Belgium.
  • Grutters JC; University of Applied Sciences Utrecht, Institute of Movement Studies, Faculty of Health Care, Utrecht, The Netherlands.
Sarcoidosis Vasc Diffuse Lung Dis ; 35(4): 317-326, 2018.
Article de En | MEDLINE | ID: mdl-32476919
Background and objective: Patients with pulmonary fibrosis (PF) have a clear exercise intolerance. The 4-meter-gait-speed (4MGS) test and the 5-repetitions-sit-to-stand (5STS) test are easy, inexpensive and reliable measures of functional performance. Both tests have been validated in healthy adults and patients with chronic obstructive pulmonary disease. 4MGS test and 5STS test have not been studied in patients with PF. Methods: In this cross-sectional clinimetric validation study 51 PF patients conducted in random order the 4MGS test, 5STS test and the 6-min walk test (6MWT) on a single day. Additionally, body weight, height, lean body mass, health-related quality of life, disease severity, handgrip strength, dyspnoea and leg fatigue were assessed. The setting was a tertiary referral center for Interstitial Lung Diseases. Results: Patients had a diagnosis of idiopathic pulmonary fibrosis (IPF, 37%), PF other than IPF (47%), or unclassified (16%). Patients walked 453±111m in six minutes. Moreover, it took the patients 2.0±0.5s to walk 4 m, and 12.0±3.8s for the 5STS test. The 4MGS test (r = 0.77; p<0.01) and the 5STS test (r = -0.41; p<0.01) correlated significantly with the distance walked in 6MWT. Indeed, 4MGS combined with handgrip strength and Medical Research Council dyspnoea grade could explain 75% of the variance in 6MWD. Conclusions: 4-meter-gait-speed and 5-repetitions sit-to-stand are significantly and independently correlated with the 6-minute walk distance in patients with pulmonary fibrosis. Indeed, 4-meter-gait-speed test may serve as a simple initial field test to assess exercise performance in patients with pulmonary fibrosis. (Sarcoidosis Vasc Diffuse Lung Dis 2018; 35: 317-326).
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Aspects: Patient_preference Langue: En Journal: Sarcoidosis Vasc Diffuse Lung Dis Sujet du journal: ALERGIA E IMUNOLOGIA / ANGIOLOGIA Année: 2018 Type de document: Article Pays d'affiliation: Pays-Bas Pays de publication: Italie

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Aspects: Patient_preference Langue: En Journal: Sarcoidosis Vasc Diffuse Lung Dis Sujet du journal: ALERGIA E IMUNOLOGIA / ANGIOLOGIA Année: 2018 Type de document: Article Pays d'affiliation: Pays-Bas Pays de publication: Italie