Your browser doesn't support javascript.
loading
[Ga3+ 8 Sm3+ 2 , Ga3+ 8 Tb3+ 2 ] Metallacrowns are Highly Promising Ratiometric Luminescent Molecular Nanothermometers Operating at Physiologically Relevant Temperatures.
Salerno, Elvin V; Zeler, Justyna; Eliseeva, Svetlana V; Hernández-Rodríguez, Miguel A; Carneiro Neto, Albano N; Petoud, Stéphane; Pecoraro, Vincent L; Carlos, Luís D.
Affiliation
  • Salerno EV; Department of Chemistry, University of Michigan, Ann Arbor, MI, 48108, USA.
  • Zeler J; Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, Aveiro, Portugal.
  • Eliseeva SV; Faculty of Chemistry, University of Wroclaw, Wroclaw, Poland.
  • Hernández-Rodríguez MA; Centre de Biophysique Moléculaire, CNRS, UPR 4301, 45071, Orléans Cedex 2, France.
  • Carneiro Neto AN; Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, Aveiro, Portugal.
  • Petoud S; Phantom-g, CICECO-Aveiro Institute of Materials, Department of Physics, University of Aveiro, Campus de Santiago, Aveiro, Portugal.
  • Pecoraro VL; Centre de Biophysique Moléculaire, CNRS, UPR 4301, 45071, Orléans Cedex 2, France.
  • Carlos LD; Department of Chemistry, University of Michigan, Ann Arbor, MI, 48108, USA.
Chemistry ; 26(61): 13792-13796, 2020 Nov 02.
Article de En | MEDLINE | ID: mdl-32663350
ABSTRACT
Nanothermometry is the study of temperature at the submicron scale with a broad range of potential applications, such as cellular studies or electronics. Molecular luminescent-based nanothermometers offer a non-contact means to record these temperatures with high spatial resolution and thermal sensitivity. A luminescent-based molecular thermometer comprised of visible-emitting Ga3+ /Tb3+ and Ga3+ /Sm3+ metallacrowns (MCs) achieved remarkable relative thermal sensitivity associated with very low temperature uncertainty of Sr =1.9 % K-1 and δT<0.045 K, respectively, at 328 K, as an aqueous suspension of polystyrene nanobeads loaded with the corresponding MCs. To date, they are the ratiometric molecular nanothermometers offering the highest level of sensitivity in the physiologically relevant temperature range.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Composés organométalliques / Samarium / Terbium / Gallium Langue: En Journal: Chemistry Sujet du journal: QUIMICA Année: 2020 Type de document: Article Pays d'affiliation: États-Unis d'Amérique

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Composés organométalliques / Samarium / Terbium / Gallium Langue: En Journal: Chemistry Sujet du journal: QUIMICA Année: 2020 Type de document: Article Pays d'affiliation: États-Unis d'Amérique
...