Your browser doesn't support javascript.
loading
Xurography-Enabled Thermally Transferred Carbon Nanomaterial-Based Electrochemical Sensors on Polyethylene Terephthalate-Ethylene Vinyl Acetate Films.
Hernández-Rodríguez, Juan F; Della Pelle, Flavio; Rojas, Daniel; Compagnone, Dario; Escarpa, Alberto.
Affiliation
  • Hernández-Rodríguez JF; Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.
  • Della Pelle F; Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.
  • Rojas D; Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy.
  • Compagnone D; Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.
  • Escarpa A; Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy.
Anal Chem ; 92(19): 13565-13572, 2020 10 06.
Article de En | MEDLINE | ID: mdl-32869640
ABSTRACT
A novel benchtop approach to fabricate xurography-enabled thermally transferred (XTT) carbon nanomaterial-based electrochemical sensors is proposed. Filtered nanomaterial (NM) films were transferred from Teflon filters to polyethylene terephthalate-ethylene vinyl acetate (PET-EVA) substrates by a temperature-driven approach. Customized PET-EVA components were xurographically patterned by a cutting plotter. The smart design of PET-EVA films enabled us to selectively transfer the nanomaterial to the exposed EVA side of the substrate. Hence, the substrate played an active role in selectively controlling where nanomaterial transfer occurred allowing us to design different working electrode geometries. Counter and reference electrodes were integrated by a stencil-printing approach, and the whole device was assembled by thermal lamination. To prove the versatility of the technology, XTT materials were exclusively made of carbon black (XTT-CB), multiwalled carbon nanotubes (XTT-MWCNTs), and single-walled carbon nanotubes (XTT-SWCNTs). Their electrochemical behavior was carefully studied and was found to be highly dependent on the amount and type of NM employed. XTT-SWCNTs were demonstrated to be the best-performing sensors, and they were employed for the determination of l-tyrosine (l-Tyr) in human plasma from tyrosinemia-diagnosed patients. High analytical performance toward l-Tyr (linear range of 0.5-100 µM, LOD = 0.1 µM), interelectrode precision (RSD ip,a = 3%, n = 10; RSD calibration slope = 4%, n = 3), and accurate l-Tyr quantification in plasma samples with low relative errors (≤7%) compared to the clinical declared values were obtained. The proposed benchtop approach is cost-effective and straightforward, does not require sophisticated facilities, and can be potentially employed to develop pure or hybrid nanomaterial-based electrodes.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Polyvinyles / Température / Carbone / Téréphtalate polyéthylène / Nanostructures / Techniques électrochimiques Langue: En Journal: Anal Chem Année: 2020 Type de document: Article Pays d'affiliation: Espagne

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Polyvinyles / Température / Carbone / Téréphtalate polyéthylène / Nanostructures / Techniques électrochimiques Langue: En Journal: Anal Chem Année: 2020 Type de document: Article Pays d'affiliation: Espagne