Your browser doesn't support javascript.
loading
Visualization of flow dynamics in the portal circulation using 320-detector-row computed tomography: a feasibility study.
Kageyama, Ken; Yamamoto, Akira; Jogo, Atsushi; Izuta, Shinichiro; Himoto, Daisuke; Kakimi, Akihiko; Sohgawa, Etsuji; Miki, Yukio.
Affiliation
  • Kageyama K; Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka City University, 1-4-3 Asahi-machi, Abeno-ku, Osaka, 545-8585, Japan. kageyama@med.osaka-cu.ac.jp.
  • Yamamoto A; Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka City University, 1-4-3 Asahi-machi, Abeno-ku, Osaka, 545-8585, Japan.
  • Jogo A; Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka City University, 1-4-3 Asahi-machi, Abeno-ku, Osaka, 545-8585, Japan.
  • Izuta S; Department of Central Radiology, Osaka City University Hospital, 1-5-7 Asahi-machi, Abeno-ku, Osaka, 545-8586, Japan.
  • Himoto D; Department of Central Radiology, Osaka City University Hospital, 1-5-7 Asahi-machi, Abeno-ku, Osaka, 545-8586, Japan.
  • Kakimi A; Department of Central Radiology, Osaka City University Hospital, 1-5-7 Asahi-machi, Abeno-ku, Osaka, 545-8586, Japan.
  • Sohgawa E; Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka City University, 1-4-3 Asahi-machi, Abeno-ku, Osaka, 545-8585, Japan.
  • Miki Y; Department of Diagnostic and Interventional Radiology, Graduate School of Medicine, Osaka City University, 1-4-3 Asahi-machi, Abeno-ku, Osaka, 545-8585, Japan.
Eur Radiol Exp ; 5(1): 1, 2021 01 12.
Article de En | MEDLINE | ID: mdl-33432529
ABSTRACT
Multidetector row computed tomography (CT) scanners perform dynamic scanning and have a wide scan range. Time-resolved three-dimensional CT (i.e., 4D CT) has recently enabled visualization of flow in neurovascular vessels. We hypothesized that 4D CT technology would be a useful and non-invasive method for visualizing the flow dynamics of the portal circulation. The aim of this study was to evaluate the technical feasibility of 4D CT for visualizing flow dynamics in the portal circulation using 320-detector-row CT. 4D CT images of 18 consecutive patients with portal circulation including gastrorenal shunt were retrospectively evaluated for their ability to generate flow dynamics of the portal circulation. Flow dynamics could be visualized by 4D CT in 68 of the 72 vessels in the portal vein, splenic vein, superior mesenteric vein, and gastrorenal shunt. Flow direction could not be identified in four vessels, all of them being superior mesenteric veins. Flow direction was recognized on 4D CT in the 68 vessels of the portal circulation. A preliminary validation study revealed that flow direction of all 19 vessels in the portal circulation had concordance between 4D CT and color Doppler ultrasound. 4D CT could visualize flow dynamics of the portal circulation.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Veine porte / Veine liénale Type d'étude: Observational_studies Limites: Humans Langue: En Journal: Eur Radiol Exp Année: 2021 Type de document: Article Pays d'affiliation: Japon

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Veine porte / Veine liénale Type d'étude: Observational_studies Limites: Humans Langue: En Journal: Eur Radiol Exp Année: 2021 Type de document: Article Pays d'affiliation: Japon
...