Intraoperative ECMO assistance during TAVI for aortic insufficiency in an Asian patient with LVAD support.
ESC Heart Fail
; 8(4): 3418-3421, 2021 08.
Article
de En
| MEDLINE
| ID: mdl-34085412
ABSTRACT
A 69-year-old male underwent concomitant left ventricular assist device (LVAD) implantation and aortic valve repair procedure for moderate aortic insufficiency (AI). Due to recurrence of symptomatic heart failure and post-repair AI deterioration from trivial to moderate-to-severe insufficiency 2 months later, transcatheter aortic valve implantation (TAVI) was arranged. During TAVI, intraoperative extracorporeal membrane oxygenation was used to maintain stable haemodynamics and to ensure a safe environment for prosthesis deployment. Postoperative 5 month follow-up revealed no AI and no paravalvular leakage.
Mots clés
Texte intégral:
1
Collection:
01-internacional
Base de données:
MEDLINE
Sujet principal:
Insuffisance aortique
/
Oxygénation extracorporelle sur oxygénateur à membrane
/
Dispositifs d'assistance circulatoire
/
Remplacement valvulaire aortique par cathéter
Type d'étude:
Diagnostic_studies
/
Etiology_studies
Limites:
Aged
/
Humans
/
Male
Langue:
En
Journal:
ESC Heart Fail
Année:
2021
Type de document:
Article
Pays d'affiliation:
Taïwan