Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated above Ground.
Phys Rev Lett
; 127(6): 061801, 2021 Aug 06.
Article
de En
| MEDLINE
| ID: mdl-34420312
ABSTRACT
We present limits on spin-independent dark matter-nucleon interactions using a 10.6 g Si athermal phonon detector with a baseline energy resolution of σ_{E}=3.86±0.04(stat)_{-0.00}^{+0.19}(syst) eV. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from 93 to 140 MeV/c^{2}, with a raw exposure of 9.9 g d acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.