Your browser doesn't support javascript.
loading
Slow Passivation and Inverted Hysteresis for Hybrid Tin Perovskite Solar Cells Attaining 13.5% via Sequential Deposition.
Jokar, Efat; Chuang, He-Shiang; Kuan, Chun-Hsiao; Wu, Hui-Ping; Hou, Cheng-Hung; Shyue, Jing-Jong; Wei-Guang Diau, Eric.
Affiliation
  • Jokar E; Department of Applied Chemistry and Institute of Molecular Science, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu 30010, Taiwan.
  • Chuang HS; Center for Emergent Functional Matter Science, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu 30010, Taiwan.
  • Kuan CH; Department of Applied Chemistry and Institute of Molecular Science, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu 30010, Taiwan.
  • Wu HP; Department of Applied Chemistry and Institute of Molecular Science, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu 30010, Taiwan.
  • Hou CH; Department of Applied Chemistry and Institute of Molecular Science, National Chiao Tung University, 1001 Ta-Hsueh Road, Hsinchu 30010, Taiwan.
  • Shyue JJ; Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan.
  • Wei-Guang Diau E; Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan.
J Phys Chem Lett ; 12(41): 10106-10111, 2021 Oct 21.
Article de En | MEDLINE | ID: mdl-34633820
ABSTRACT
Herein, we report a sequential deposition procedure to passivate the surface of a hybrid mixed cationic tin perovskite (E1G20) with phenylhydrazinium thiocyanate (PHSCN) dissolved in trifluoroethanol solvent. The photoluminescence lifetime of the PHSCN film was enhanced by a factor of 6, while the charge-extraction rate from perovskite to C60 layer was enhanced by a factor of 2.5, in comparison to those of the E1G20 film. A slow surface passivation was observed; the performance of the PHSCN device improved upon increasing the storage period to attain an efficiency of 13.5% for a current-voltage scan in the forward bias direction. An inverted effect of hysteresis was observed in that the efficiency of the forward scan was greater than that of the reverse scan. An ion-migration model as a result of the effect of the phenylhydrazinium surface passivation is proposed to account for the observed phenomena. The device was stable upon shelf storage in a glovebox for 3000 h.

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Type d'étude: Prognostic_studies Langue: En Journal: J Phys Chem Lett Année: 2021 Type de document: Article Pays d'affiliation: Taïwan

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Type d'étude: Prognostic_studies Langue: En Journal: J Phys Chem Lett Année: 2021 Type de document: Article Pays d'affiliation: Taïwan
...