Your browser doesn't support javascript.
loading
Magnetic resonance imaging-guided radiotherapy for intermediate- and high-risk prostate cancer: Trade-off between planning target volume margin and online plan adaption.
Tetar, Shyama U; Bruynzeel, Anna M E; Verweij, Lisa; Bohoudi, Omar; Slotman, Berend J; Rosario, Tezontl; Palacios, Miguel A; Lagerwaard, Frank J.
Affiliation
  • Tetar SU; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Bruynzeel AME; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Verweij L; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Bohoudi O; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Slotman BJ; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Rosario T; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Palacios MA; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
  • Lagerwaard FJ; Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, de Boelelaan 1117, 1081 HV Amsterdam, The Netherlands.
Phys Imaging Radiat Oncol ; 23: 92-96, 2022 Jul.
Article de En | MEDLINE | ID: mdl-35844255
ABSTRACT
Magnetic resonance-guided radiotherapy with daily plan adaptation for intermediate- and high-risk prostate cancer is time and labor intensive. Fifty adapted plans with 3 mm planning target volume (PTV)-margin were compared with non-adapted plans using 3 or 5 mm margins. Adequate (V95% ≥ 95%) prostate coverage was achieved in 49 fractions with 5 mm PTV without plan adaptation, however, coverage of the seminal vesicles (SV) was insufficient in 15 of 50 fractions. There was no insufficient coverage for prostate and SV using plan adaptation with 3 mm. Hence, daily adaptation is recommended to obtain adequate SV-coverage when using 3 mm PTV.
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Type d'étude: Etiology_studies / Risk_factors_studies Langue: En Journal: Phys Imaging Radiat Oncol Année: 2022 Type de document: Article Pays d'affiliation: Pays-Bas

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Type d'étude: Etiology_studies / Risk_factors_studies Langue: En Journal: Phys Imaging Radiat Oncol Année: 2022 Type de document: Article Pays d'affiliation: Pays-Bas