Your browser doesn't support javascript.
loading
An optimized method for neutron dose evaluation based on24Na activity distribution in the human body.
Xu, Xu; Xiaomin, Zhang; Jing, Ning; Xiangdong, Xie; Yong, Yuan.
Affiliation
  • Xu X; Beijing Institute of Radiation Medicine, Beijing, People's Republic of China.
  • Xiaomin Z; Beijing Institute of Radiation Medicine, Beijing, People's Republic of China.
  • Jing N; Beijing Institute of Radiation Medicine, Beijing, People's Republic of China.
  • Xiangdong X; Beijing Institute of Radiation Medicine, Beijing, People's Republic of China.
  • Yong Y; Beijing Institute of Radiation Medicine, Beijing, People's Republic of China.
J Radiol Prot ; 43(1)2023 02 10.
Article de En | MEDLINE | ID: mdl-36649650
The neutron dose resulting from external irradiation can be evaluated by measuring the counts of characteristicγrays produced by24Na in the human body. The detection geometry with the highest detection efficiency for measuring the whole-body24Na activity has not been studied. In this work, the MCNP code is used to calculate the spatial distribution of24Na in the human body irradiated by neutrons with different energies in different irradiation geometries. The fluence distribution of24Na characteristicγrays on the body surface is calculated. The counts of24Na characteristicγrays induced by monochromatic neutron irradiation are simulated to fit the scenarios of neutron irradiation by a continuous energy spectrum neutron. When the spontaneous neutrons from252Cf with 1Gy dose irradiate the human body, (3.63-4.35) × 1010 24Na atoms are produced. The lower detection limit for the neutron absorption dose is reduced from ∼100 to less than 1 mGy when the radiation detector is placed over the back of the human body close to the liver. The relative error between the measured counts of24Na characteristic γ rays caused by252Cf neutron irradiation and the counts fitted by monochromatic neutron irradiation data is less than 5.7%. The neutron dose received from a continuous energy spectrum neutron can be acquired quickly and accurately by weighted summing of the data for monochromatic neutron irradiations calculated in this paper, which is more convenient and practical than the previous method.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Corps humain / Neutrons Limites: Humans Langue: En Journal: J Radiol Prot Sujet du journal: RADIOLOGIA Année: 2023 Type de document: Article Pays de publication: Royaume-Uni

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Corps humain / Neutrons Limites: Humans Langue: En Journal: J Radiol Prot Sujet du journal: RADIOLOGIA Année: 2023 Type de document: Article Pays de publication: Royaume-Uni