Your browser doesn't support javascript.
loading
Flow injection chemiluminescence determination of acetochlor and cartap-HCl in freshwater samples using an acidic KMnO4 -rhodamine-B reaction system.
Nisa, Khair Un; Kakar, Attiq Ur Rehman; Asghar, Muhammad; Shah, Arif.
Affiliation
  • Nisa KU; Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
  • Kakar AUR; Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
  • Asghar M; Department of Chemical Engineering and Analytical Chemistry, University of Barcelona, Marti i Franques 1-11, Barcelona, Spain.
  • Samiullah; Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
  • Naqeebullah; Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
  • Niamatullah; Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
  • Shah A; Department of Chemistry, University of Balochistan, Sariab Road, Quetta, Pakistan.
Luminescence ; 38(5): 647-661, 2023 May.
Article de En | MEDLINE | ID: mdl-36967642
A flow injection (FI) methodology using the acidic potassium permanganate (KMnO4 )-rhodamine-B (Rh-B) reaction with chemiluminescence (CL) detection was established to determine acetochlor and cartap-HCl pesticides in freshwater samples. Experimental parameters were optimized, and Chelex-100 cationic exchanger mini column and solid-phase extraction (SPE) were used as phase separation techniques. Linear calibration curves were observed for the standard solutions of acetochlor and cartap-HCl over the ranges 0.005-2.0 mg L-1 [y = 1155.8x + 57.551, R2  = 0.9999 (n = 8)] and 0.005-1.0 mg L-1 [y = 979.76x + 14.491, R2  = 0.9998 (n = 8)] with LODs and LOQs of 7.5 × 10-4 and 8.0 × 10-4  mg L-1 (3σ blank) and 2.5 × 10-3 and 2.7 × 10-3  mg L-1 (10σ blank), respectively, with an injection throughput of 140 h-1 . These methods were used to estimate acetochlor and cartap-HCl with or without the SPE procedure, respectively, in spiked freshwater samples. Results obtained were not significantly different at a 95% confidence level to those of other reported methods. Recoveries for acetochlor and cartap-HCl were obtained over the ranges 93-112% (RSD = 1.9-3.6%) and 98-109% (RSD = 1.7-3.8%), respectively. The most probable CL reaction mechanism was explored.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Acides / Luminescence Langue: En Journal: Luminescence Sujet du journal: BIOFISICA / BIOQUIMICA Année: 2023 Type de document: Article Pays d'affiliation: Pakistan Pays de publication: Royaume-Uni

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Acides / Luminescence Langue: En Journal: Luminescence Sujet du journal: BIOFISICA / BIOQUIMICA Année: 2023 Type de document: Article Pays d'affiliation: Pakistan Pays de publication: Royaume-Uni