Effect of Various Lasers With or Without Systemp.desensitizer on Dentine Tubules: An In Vitro Scanning Electron Microscopy Analysis.
Photobiomodul Photomed Laser Surg
; 41(7): 350-357, 2023 Jul.
Article
de En
| MEDLINE
| ID: mdl-37384905
Objective: The current study was carried out to evaluate the effects of laser and Systemp.desensitizer therapy. Further, scanning electron microscopy (SEM) was used to determine the effects of individual or combined desensitizers on human dentinal tubules. Background: The most common clinical condition that makes people uncomfortable is dentin hypersensitivity (DH). Both lasers and drugs that reduce sensitivity have been used to treat DH. Materials and methods: A total of 100 dentinal samples were taken from newly extracted third molars (affected) and divided into 10 groups (A to J), that is, control (A); Systemp.desensitizer (B); diode laser (980 nm) (C); Nd:YAG laser (D); Er:YAG laser (E); Er,Cr:YSGG laser (F); Systemp.desensitizer + diode laser (G); Systemp.desensitizer + Nd:YAG laser (H); Systemp.desensitizer + Er:YAG laser (I); and Systemp.desensitizer + Er,Cr:YSGG laser (J). SEM was used to evaluate the dentinal specimens in each group (longitudinal and transverse portions), and then images of each sample were captured (20 images/sample). In addition, the number of open dentinal tubules was counted and then the occlusion depth in dentinal tubules was measured. Mann-Whitney and Kruskal-Wallis tests were employed to analyze the obtained data. Results: All treatment procedures and protocols were effective in blocking dentinal tubules (p < 0.05). Compared with the other groups, dentinal tubules in the laser and laser combination therapy groups were significantly obstructed (p < 0.05). Diode and Nd:YAG lasers with or without Systemp.desensitizer showed significantly more tubule occlusion and greater sealing depth than Er:YAG and Er,Cr:YSGG lasers with or without Systemp.desensitizer (p < 0.05). Conclusions: In summary, lasers alone or in combination can play a significant role in occluding the dentinal tubules. However, combining the diode or Nd:YAG laser with Systemp.desensitizers is a more effective treatment strategy and may have immediate and long-lasting effects.
Mots clés
Texte intégral:
1
Collection:
01-internacional
Base de données:
MEDLINE
Sujet principal:
Dentine
/
Lasers à solide
Type d'étude:
Guideline
Limites:
Humans
Langue:
En
Journal:
Photobiomodul Photomed Laser Surg
Année:
2023
Type de document:
Article
Pays de publication:
États-Unis d'Amérique