Your browser doesn't support javascript.
loading
Determination of rhein and physcion in rhubarb by microchip capillary electrophoresis in mixed hydro-organic solvent combined with laser-induced fluorescence detection.
Chen, ShengHao; Liang, YanLan; Li, YuanYuan; Sun, Yue; He, Yang.
Affiliation
  • Chen S; School of Traditional Chinese Medicine, Guangdong Pharmaceutical University, Guangzhou, China.
  • Liang Y; Experimental Center of Zhongshan Campus, Guangdong Pharmaceutical University, Guangzhou, China.
  • Li Y; Guangdong Cosmetics Engineering & Technology Research Center, Zhongshan, China.
  • Sun Y; School of Traditional Chinese Medicine, Guangdong Pharmaceutical University, Guangzhou, China.
  • He Y; Experimental Center of Zhongshan Campus, Guangdong Pharmaceutical University, Guangzhou, China.
J Sep Sci ; 46(19): e2300192, 2023 Oct.
Article de En | MEDLINE | ID: mdl-37507831
ABSTRACT
Microchip capillary electrophoresis in mixed hydro-organic solvent combined with laser-induced fluorescence detection was developed for the separation and detection of physcion and rhein in rhubarb. In contrast to the conventional capillary electrophoresis method, ammonium acetate-dimethyl sulfoxide was used as the basic buffer system in this method. The effects of background buffer, buffer apparent pH*, buffer concentration, water ratio, sample preparation method, and separation voltage on separation and detection were investigated. Optimized separation and detection conditions were obtained the buffer consisted of 20 mmol/L of ammonium acetate in hydro-organic solvent composed dimethyl sulfoxide, formamide, and water mixed at 60/20/20 (v/v/v) ratio. The separation voltage was 1.9 kV. Under these conditions, the physcion, rhein, and other components of rhubarb can be completely separated within 150 s. Under the methodological verification, good linearity (R ≥ 0.9995) for physcion and rhein, and low limits of detection (0.085 µg·mL-1 and 0.077 µg·mL-1 , respectively), satisfactory peak area precisions, migration time precisions (1.74%-3.09%), and accuracy (recovery rate 97.8% and 101.4%) were achieved. It is shown that the proposed method is simple, efficient, fast, sensitive, simple instrument, consumes few samples, has low operating cost, and is linear.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Rheum / Électrophorèse sur puce Type d'étude: Diagnostic_studies Langue: En Journal: J Sep Sci Année: 2023 Type de document: Article Pays d'affiliation: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Rheum / Électrophorèse sur puce Type d'étude: Diagnostic_studies Langue: En Journal: J Sep Sci Année: 2023 Type de document: Article Pays d'affiliation: Chine