Your browser doesn't support javascript.
loading
Evaluation of the ear ossicles with photon-counting detector CT.
Takahashi, Yuka; Higaki, Fumiyo; Sugaya, Akiko; Asano, Yudai; Kojima, Katsuhide; Morimitsu, Yusuke; Akagi, Noriaki; Itoh, Toshihide; Matsui, Yusuke; Hiraki, Takao.
Affiliation
  • Takahashi Y; Department of Radiology, Okayama University Hospital, 2-5-1 Shikata-Cho, Kitaku, Okayama, 700-8558, Japan.
  • Higaki F; Department of Radiology, Okayama University Hospital, 2-5-1 Shikata-Cho, Kitaku, Okayama, 700-8558, Japan. fumiyo.higaki@okayama-u.ac.jp.
  • Sugaya A; Department of Otolaryngology-Head and Neck Surgery, Okayama University Hospital, Okayama, Japan.
  • Asano Y; Department of Radiology, Okayama University Hospital, 2-5-1 Shikata-Cho, Kitaku, Okayama, 700-8558, Japan.
  • Kojima K; Department of Radiology, Okayama University Hospital, 2-5-1 Shikata-Cho, Kitaku, Okayama, 700-8558, Japan.
  • Morimitsu Y; Department of Radiological Technology, Okayama University Hospital, Okayama, Japan.
  • Akagi N; Department of Radiological Technology, Okayama University Hospital, Okayama, Japan.
  • Itoh T; Department of CT-Research and Collaboration, Siemens Healthineers, Tokyo, Japan.
  • Matsui Y; Department of Radiology, Okayama University Faculty of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
  • Hiraki T; Department of Radiology, Okayama University Faculty of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan.
Jpn J Radiol ; 42(2): 158-164, 2024 Feb.
Article de En | MEDLINE | ID: mdl-37633874
ABSTRACT
Recently, computed tomography with photon-counting detector (PCD-CT) has been developed to enable high-resolution imaging at a lower radiation dose. PCD-CT employs a photon-counting detector that can measure the number of incident X-ray photons and their energy. The newly released PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Forchheim, Germany) has been in clinical use at our institution since December 2022. The PCD-CT offers several advantages over current state-of-the-art energy-integrating detector CT (EID-CT). The PCD-CT does not require septa to create a detector channel, while EID-CT does. Therefore, downsizing the anode to achieve higher resolution does not affect the dose efficiency of the PCD-CT. CT is an indispensable modality for evaluating ear ossicles. The ear ossicles and joints are clearly depicted by PCD-CT. In particular, the anterior and posterior legs of the stapes, which are sometimes unclear on conventional CT scans, can be clearly visualized. We present cases of congenital anomalies of the ossicular chain, ossicular chain dislocation, tympanosclerosis, and cholesteatoma in which PCD-CT was useful. This short article reports the usefulness of PCD-CT in the 3D visualization of the ear ossicles.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Amélioration d'image radiographique / Tomodensitométrie Limites: Humans Langue: En Journal: Jpn J Radiol Sujet du journal: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Année: 2024 Type de document: Article Pays d'affiliation: Japon Pays de publication: JAPAN / JAPON / JAPÃO / JP

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Amélioration d'image radiographique / Tomodensitométrie Limites: Humans Langue: En Journal: Jpn J Radiol Sujet du journal: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Année: 2024 Type de document: Article Pays d'affiliation: Japon Pays de publication: JAPAN / JAPON / JAPÃO / JP