Your browser doesn't support javascript.
loading
Sustainable and cost-effective MAS DNP-NMR at 30 K with cryogenic sample exchange.
Paul, Subhradip; Bouleau, Eric; Reynard-Feytis, Quentin; Arnaud, Jean-Pierre; Bancel, Florian; Rollet, Bertrand; Dalban-Moreynas, Pierre; Reiter, Christian; Purea, Armin; Engelke, Frank; Hediger, Sabine; De Paëpe, Gaël.
Affiliation
  • Paul S; Univ. Grenoble. Alpes, CEA, CNRS, IRIG, MEM, 38000 Grenoble, France.
  • Bouleau E; Univ. Grenoble Alpes, CEA, IRIG, DSBT, 38000 Grenoble, France.
  • Reynard-Feytis Q; Univ. Grenoble. Alpes, CEA, CNRS, IRIG, MEM, 38000 Grenoble, France.
  • Arnaud JP; Univ. Grenoble Alpes, CEA, IRIG, DSBT, 38000 Grenoble, France.
  • Bancel F; Univ. Grenoble Alpes, CEA, IRIG, DSBT, 38000 Grenoble, France.
  • Rollet B; Univ. Grenoble Alpes, CEA, IRIG, DSBT, 38000 Grenoble, France.
  • Dalban-Moreynas P; Univ. Grenoble Alpes, CEA, IRIG, DSBT, 38000 Grenoble, France.
  • Reiter C; Bruker Biospin, 76275 Ettlingen, Germany.
  • Purea A; Bruker Biospin, 76275 Ettlingen, Germany.
  • Engelke F; Bruker Biospin, 76275 Ettlingen, Germany.
  • Hediger S; Univ. Grenoble. Alpes, CEA, CNRS, IRIG, MEM, 38000 Grenoble, France.
  • De Paëpe G; Univ. Grenoble. Alpes, CEA, CNRS, IRIG, MEM, 38000 Grenoble, France. Electronic address: gael.depaepe@cea.fr.
J Magn Reson ; 356: 107561, 2023 Nov.
Article de En | MEDLINE | ID: mdl-37837749
ABSTRACT
We report here instrumental developments to achieve sustainable, cost-effective cryogenic Helium sample spinning in order to conduct dynamic nuclear polarisation (DNP) and solid-state NMR (ssNMR) at ultra-low temperatures (<30 K). More specifically, we describe an efficient closed-loop helium system composed of a powerful heat exchanger (95% efficient), a single cryocooler, and a single helium compressor to power the sample spinning and cooling. The system is integrated with a newly designed triple-channel NMR probe that minimizes thermal losses without compromising the radio frequency (RF) performance and spinning stability (±0.05%). The probe is equipped with an innovative cryogenic sample exchange system that allows swapping samples in minutes without introducing impurities in the closeloop system. We report that significant gain in sensitivity can be obtained at 30-40 K on large micro-crystalline molecules with unfavorable relaxation timescales, making them difficult or impossible to polarize at 100 K. We also report rotor-synchronized 2D experiments to demonstrate the stability of the system.