Your browser doesn't support javascript.
loading
[Determination of furosine in liquid milk by high performance liquid chromatography-quadrupole time-of-flight mass spectrometry].
Yao, Gui-Hong; Ling, Yun; Zhang, Yu-Jia; Xing, Shi-Ge; Yao, Mei-Yi; Guo, Wei; Zhang, Feng.
Affiliation
  • Yao GH; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
  • Ling Y; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
  • Zhang YJ; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
  • Xing SG; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
  • Yao MY; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
  • Guo W; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
  • Zhang F; Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
Se Pu ; 41(11): 1038-1043, 2023 Nov.
Article de Zh | MEDLINE | ID: mdl-37968823
Furosine is often used both domestically and internationally as an indicator of the degree of heating to evaluate milk quality. However, in actual detection, the complexity of the milk matrix may lead to the inaccurate quantification of furosine in liquid milk. Therefore, in this study, an efficient and accurate method based on high performance liquid chromatography-quadrupole time-of-flight mass spectrometry (HPLC-Q-TOF/MS) was established to determine furosine in liquid milk. A 2.00 mL milk sample was hydrolyzed with 5 mL 12.00 mol/L hydrochloric acid solution and 1 mL water at 110 ℃ for 12 h. After hydrolysis, vortex-mixing and filtration were performed. The filtrate was diluted six times with 6.00 g/L ammonium acetate solution and then analyzed. Gradient elution was performed with 0.20% formic acid aqueous solution and acetonitrile solution as mobile phases, followed by chromatographic separation on an AQ-C18 column (150 mm×3.5 mm, 5 µm). The data were collected by Q-TOF/MS with an electrospray ionization source operated in positive-ion mode. The accuracy of the quantification of furosine in milk was assessed by investigating the effects of the hydrochloric acid concentration (0.30, 1.25, and 3.00 mol/L) in the furosine solution on the MS response. The results showed that high hydrochloric acid concentrations inhibited the response signals. A good linear relationship was obtained in the mass concentration range of 0.05-2.00 mg/L, with a correlation coefficient (r) of 0.994. The limit of detection of the method was 0.50 mg/100 g, which meets the requirements of actual sample detection. The average recoveries of furosine ranged from 79.9% to 119.7% at three spiked levels of 1.52, 3.03, and 15.17 mg/100 g, with relative standard deviations of 1.4%-2.6%. The method was applied to detect 303 samples from 101 batches of pasteurized milk sold in the market, and the contents of furosine in these samples ranged from 5.1 to 11.9 mg/100 g. The proposed method is characterized with high efficiency, recovery, sensitivity, and accuracy. Thus, it can be used for the determination of large quantities of samples and provides technical support for the continuous promotion of the high-quality development of the whole dairy industry chain.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Lait / Acide chlorhydrique Limites: Animals Langue: Zh Journal: Se Pu Année: 2023 Type de document: Article Pays d'affiliation: Chine Pays de publication: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Lait / Acide chlorhydrique Limites: Animals Langue: Zh Journal: Se Pu Année: 2023 Type de document: Article Pays d'affiliation: Chine Pays de publication: Chine