Your browser doesn't support javascript.
loading
A Corneal Biomechanical Study Measured with a Scheimpflug Dynamic Analyser in Soft Contact Lens Wearers.
López-Muñoz, Alfredo; López-Castaño, Isabel; Torres-Parejo, Úrsula; García-Romera, Marta-C.
Affiliation
  • López-Muñoz A; Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain.
  • López-Castaño I; Research & Development Department (Miranza Virgen de Luján®), Ophthalmology Center, 41011 Seville, Spain.
  • Torres-Parejo Ú; Department of Physics of Condensed Matter, Optics Area, Vision Sciences Research Group (CIVIUS), Pharmacy School, University of Seville, 41009 Seville, Spain.
  • García-Romera MC; Department of Statistics and Operations Research, University of Grenade, 18071 Grenade, Spain.
Life (Basel) ; 13(12)2023 Dec 08.
Article de En | MEDLINE | ID: mdl-38137914
ABSTRACT
The aim of this study was to evaluate the biomechanical changes in the cornea after wearing soft contact lenses (CLs) in healthy myopic patients measured with a Corvis ST® (CST, Oculus Optikgeräte GmbH, Wetzlar, Germany) analyser. This prospective, cross-sectional, single-centre study was performed on twenty-two Caucasian patients aged between 19 and 24 years (20.64 ± 1.21 years) range. Five device-specific biomechanical parameters, the central corneal thickness (CCT), and biomechanically corrected intraocular pressure (bIOP) were measured prior to fitting and one month after CL wear. Differences between the means of the deflection amplitude ratio (DA Ratio) and the standard deviation of the DA Ratio (SD DA Ratio) pre- and post-CL wear were found to be significant (p value = 0.002 in both cases). Significant differences were found between pre- and post-CL wear values in CCT (p value = 0.013). For all other biomechanical measures, no significant differences were observed before and after treatment. A significant association was found between changes in bIOP and classification according to changes in Int. Radius (p value = 0.047) and SSI (p value = 0.026) standard deviations. The corneal biomechanical indices provided by CST demonstrate that the fitting of soft CLs is a safe optical compensation method for the stability of corneal stiffness. No significant differences were found pre- and post-CL wear in the assessment of bIOP.
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: Life (Basel) Année: 2023 Type de document: Article Pays d'affiliation: Espagne Pays de publication: Suisse

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: Life (Basel) Année: 2023 Type de document: Article Pays d'affiliation: Espagne Pays de publication: Suisse