Your browser doesn't support javascript.
loading
A new immunosensing platform based on conjugated Poly(ThidEp-co-EDOT) copolymer for resistin detection, a new obesity biomarker.
Aydin, Elif Burcu; Aydin, Muhammet; Sezgintürk, Mustafa Kemal.
Affiliation
  • Aydin EB; Scientific and Technological Research Center, Tekirdag Namik Kemal University, Tekirdag, Turkey. ebbahadir@nku.edu.tr.
  • Aydin M; Scientific and Technological Research Center, Tekirdag Namik Kemal University, Tekirdag, Turkey.
  • Sezgintürk MK; Faculty of Engineering, Bioengineering Department, Çanakkale Onsekiz Mart University, Çanakkale, Turkey.
Mikrochim Acta ; 191(1): 69, 2024 01 02.
Article de En | MEDLINE | ID: mdl-38165489
ABSTRACT
The design of a novel electrochemical impedimetric biosensor for label-free analysis of resistin, a biomarker for obesity, is reported. For the fabrication of the immunosensor, a novel approach composed of electrochemical copolymerization of double epoxy groups-substituted thiophene (ThidEp) and 3,4-Ethylenedioxythiophene (EDOT) monomers was utilized. Anti-resistin antibodies were covalently attached to the copolymer-coated electrode. The capture of resistin antigens by anti-resistin antibodies caused significant variations in charge transfer resistance (Rct) because of the immunoreactions between these proteins. Under optimum experimental variables, the changes in impedance signals were employed for the determination of resistin antigen concentration, and the prepared immunosensor based on conjugated copolymer illustrated a wide linear range between 0.0125 and 22.5 pg/mL, a low detection limit (LOD) of 3.71 fg/mL, and a good sensitivity of 1.22 kΩ pg-1mL cm2. The excellent analytical performance of the resistin immunosensor in terms of selectivity, sensitivity, repeatability, reproducibility, storage stability, and low detection limit might be attributed to the conductive copolymer film layer generation on the disposable indium tin oxide (ITO) platform. The capability of this system for the determination of resistin in human serum and saliva samples was also tested. The immunosensor results were in accordance with the enzyme-linked immunosorbent assay (ELISA) results. The matrix effects of human serum and saliva were also investigated, and the proposed immunosensor displayed good recovery ranging from 95.91 to 106.25%. The engineered immunosensor could open new avenues for obesity monitoring.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Techniques de biocapteur / Résistine Type d'étude: Diagnostic_studies Limites: Humans Langue: En Journal: Mikrochim Acta / Mikrochim. Acta (1966) / Mikrochimica acta (1966) Année: 2024 Type de document: Article Pays d'affiliation: Turquie Pays de publication: Autriche

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Techniques de biocapteur / Résistine Type d'étude: Diagnostic_studies Limites: Humans Langue: En Journal: Mikrochim Acta / Mikrochim. Acta (1966) / Mikrochimica acta (1966) Année: 2024 Type de document: Article Pays d'affiliation: Turquie Pays de publication: Autriche