ABSTRACT
In this paper, a highly sensitive ammonia (N H 3) sensor based on a polymethyl methacrylate/polyaniline (PMMA/PANI) microwire structure is designed and implemented. First, a micron-sized PMMA microwire was fabricated and connected with two tapered single-mode fibers to form a coupling structure; thus, the Mach-Zehnder (MZ) interference was successfully excited due to the good light conductivity of the PMMA. It was demonstrated that the coupling structure behaved with a high refractive index detection sensitivity of 3044 nm/RIU. To make it sensitive to N H 3, the PANI was selected to mix with PMMA and then formed a micron-level PMMA/PANI fiber. The experimental results showed that the PMMA/PANI fiber can selectively sense N H 3 with a high sensitivity of 65.3 pm/ppm. This proposed N H 3 sensor not only solves the problem of sensitive film shedding, but also possesses the advantages of good integration, high sensitivity, good selectivity, and short response time.

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: Appl Opt Année: 2024 Type de document: Article