Your browser doesn't support javascript.
loading
Preparation of magnetic amphiphilic resin microspheres via the one-step polymerization method and extraction of four glucocorticoids for HPLC-MS analysis.
Zhou, Zibo; He, Liang; Wang, Tianyi; Tang, Hongzhen; Qin, Suzi; Nan, Xueyan; Cheng, Wenbo; He, Haibo; Bai, Pengli.
Affiliation
  • Zhou Z; Department of Chemistry, College of Sciences, Shanghai University, Shanghai 200444, PR China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China.
  • He L; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China.
  • Wang T; Tianjin Guoke Medical Engineering and Technology Development Co., Ltd, Tianjin, 300300, PR China.
  • Tang H; Department of Chemistry, College of Sciences, Shanghai University, Shanghai 200444, PR China; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China.
  • Qin S; Tianjin Guoke Medical Engineering and Technology Development Co., Ltd, Tianjin, 300300, PR China. Electronic address: qinsz@sibet.ac.cn.
  • Nan X; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China.
  • Cheng W; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China; Tianjin Guoke Medical Engineering and Technology Development Co., Ltd, Tianjin, 300300, PR China.
  • He H; Department of Chemistry, College of Sciences, Shanghai University, Shanghai 200444, PR China.
  • Bai P; CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, PR China. Electronic address: baipl@sibet.ac.cn.
J Chromatogr A ; 1720: 464785, 2024 Apr 12.
Article de En | MEDLINE | ID: mdl-38458141
ABSTRACT
Amphiphilic materials can be used for sample preparation of chromatography or mass spectrometry. Amphiphilic materials with magnetic properties in combination with magnetic suction devices allow for automated sample preparation. However, conventional synthesis methods are cumbersome and not suitable for the mass production of the material. In this study, a micro-suspension polymerization method was developed to synthesize magnetic amphiphilic resin microspheres (MARMs), providing new ideas for the preparation of amphiphilic microspheres. MARMs with particle sizes ranging from 3 to 6 µm were successfully prepared, with BET surface area up to 653.2 m2/g. A magnetic solid-phase extraction method based on MARM-5 was developed for the extraction of four glucocorticoids including Cortisone, Hydrocortisone, Cortodoxone, and Corticosterone. This method had a very short adsorption time of 0.5 min and a total extraction time of only 13 min. The limit of detection for the four glucocorticoids ranged from 0.22 to 0.82 ng/L. There was a good linear relationship between sample concentration and peak area in the range of 25∼500 ng/L. Relative recovery of 98 %∼108 % and internal standard normalized matrix effect factors of 95∼114 % were obtained, and the relative standard deviation was between 2.3 % and 6.3 %. The MARMs would be used as excellent solid extraction material for glucocorticoids.