Your browser doesn't support javascript.
loading
Image-guided navigation in posterior orbital tumour surgery: a comparative cohort study.
Khan, Rizwana I; Golahmadi, Aida Kafai; Killeen, Ronan P; O' Brien, Donncha F; Murphy, Conor.
Affiliation
  • Khan RI; Department of Ophthalmology, Royal Victoria Eye and Ear Hospital, Dublin, Ireland.
  • Golahmadi AK; School of Medicine, Royal College of Surgeons Ireland University of Medicine and Health Sciences, Dublin, Ireland.
  • Killeen RP; Department of Ophthalmology, Imperial College Healthcare NHS Trust, London, UK.
  • O' Brien DF; Department of Ophthalmology, Royal Victoria Eye and Ear Hospital, Dublin, Ireland.
  • Murphy C; Department of Radiology, St. Vincent's University Hospital, Dublin, Ireland.
Orbit ; 43(5): 566-575, 2024 Oct.
Article de En | MEDLINE | ID: mdl-38687963
ABSTRACT

PURPOSE:

The posterior orbit is a confined space, harbouring neurovascular structures, frequently distorted by tumours. Image-guided navigation (IGN) has the potential to allow accurate localisation of these lesions and structures, reducing collateral damage whilst achieving surgical objectives.

METHODS:

We assessed the feasibility, effectiveness and safety of using an electromagnetic IGN for posterior orbital tumour surgery via a comparative cohort study. Outcomes from cases performed with IGN were compared with a retrospective cohort of similar cases performed without IGN, presenting a descriptive and statistical comparative analysis.

RESULTS:

Both groups were similar in mean age, gender and tumour characteristics. IGN set-up and registration were consistently achieved without significant workflow disruption. In the IGN group, fewer lateral orbitotomies (6.7% IGN, 46% non-IGN), and more transcutaneous lid and transconjunctival incisions (93% IGN, 53% non-IGN) were performed (p = .009). The surgical objective was achieved in 100% of IGN cases, with no need for revision surgery (vs 23% revision surgery in non-IGN, p = .005). There was no statistically significant difference in surgical complications.

CONCLUSION:

The use of IGN was feasible and integrated into the orbital surgery workflow to achieve surgical objectives more consistently and allowed the use of minimal access approaches. Future multicentre comparative studies are needed to explore the potential of this technology further.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Tumeurs de l'orbite / Études de faisabilité / Chirurgie assistée par ordinateur Limites: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Langue: En Journal: Orbit Année: 2024 Type de document: Article Pays d'affiliation: Irlande Pays de publication: Royaume-Uni

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Tumeurs de l'orbite / Études de faisabilité / Chirurgie assistée par ordinateur Limites: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Langue: En Journal: Orbit Année: 2024 Type de document: Article Pays d'affiliation: Irlande Pays de publication: Royaume-Uni