Your browser doesn't support javascript.
loading
In Vitro Performance of a Long-Range Surface Plasmon Hydrogel Aptasensor for Continuous and Real-Time Vancomycin Measurement in Human Serum.
Taguchi, Yui; Toma, Koji; Iitani, Kenta; Arakawa, Takahiro; Iwasaki, Yasuhiko; Mitsubayashi, Kohji.
Affiliation
  • Taguchi Y; Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
  • Toma K; College of Engineering, Shibaura Institute of Technology, 3-7-5 Toyosu, Koto-ku, Tokyo 135-8548, Japan.
  • Iitani K; Department of Biomedical Devices and Instrumentation, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
  • Arakawa T; Department of Electric and Electronic Engineering, Tokyo University of Technology, 1404-1 Katakura, Hachioji City, Tokyo 192-0982, Japan.
  • Iwasaki Y; Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamate-cho, Suita-shi, Osaka 564-8680, Japan.
  • Mitsubayashi K; Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
ACS Appl Mater Interfaces ; 16(22): 28162-28171, 2024 Jun 05.
Article de En | MEDLINE | ID: mdl-38767334
ABSTRACT
This study investigated the suitability of surface modification for a long-range surface plasmon (LRSP) aptasensor using two different hydrogels, aiming at real-time monitoring of vancomycin (VCM) in undiluted serum and blood. Three different layer structures were formed on a gold surface of LRSP sensor chip using poly[2-methacryloyloxyethyl phosphorylcholine (MPC)-co-N-methacryloyl-(L)-tyrosinemethylester (MAT)] (PMM) and poly[MPC-co-2-ethylhexyl methacrylate (EHMA)-co-MAT] (PMEM). The peptide aptamer for VCM was immobilized in PMM and PMEM via MAT. Among four differently prepared sensor chips, the LRSP hydrogel aptasensor with PMM, referred to as the PMM hydrogel, exhibited the highest sensor output and superior antifouling properties. Following the optimization of the PMM hydrogel preparation conditions, the shelf life of the PMM hydrogel was determined to exceed 2 weeks, and the same sensor chip could be used for 102 days without significant performance deterioration. The PMM hydrogel was then applied for VCM measurement in undiluted serum in vitro, where it demonstrated a limit of detection of 0.098 µM and a dynamic range of 0.18-100 µM, covering the therapeutic range. Additionally, the PMM hydrogel enabled the continuous measurement of various VCM concentrations in serum without rinsing and showed a concentration-dependent output in undiluted blood. These findings underscore the potential of the PMM hydrogel for real-time and direct monitoring of VCM in body fluids.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Vancomycine / Hydrogels / Résonance plasmonique de surface Limites: Humans Langue: En Journal: ACS Appl Mater Interfaces Sujet du journal: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Année: 2024 Type de document: Article Pays d'affiliation: Japon

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Vancomycine / Hydrogels / Résonance plasmonique de surface Limites: Humans Langue: En Journal: ACS Appl Mater Interfaces Sujet du journal: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Année: 2024 Type de document: Article Pays d'affiliation: Japon