Your browser doesn't support javascript.
loading
Assessment of microorganisms in drinking water disinfected by catalytic ozonation with fluorinated ceramic honeycomb and NaClO disinfectants under laboratory and pilot conditions.
Lan, Wei; Pan, Jian; Liu, Haiyang; Weng, Rui; Zeng, Yaxiong; Jin, Lili; Shi, Qiucheng; Yu, Yunsong; Guan, Baohong; Jiang, Yan.
Affiliation
  • Lan W; Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseas
  • Pan J; College of Environmental and Resource Sciences, Zhejiang University, Hangzhou, 320058, China.
  • Liu H; Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseas
  • Weng R; Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseas
  • Zeng Y; College of Chemical and Biological Engineering, Zhejiang University, Hangzhou, 320013, China.
  • Jin L; Yiwu Second Water Supply Co., Ltd., Yiwu, 322000, China.
  • Shi Q; Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseas
  • Yu Y; Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseas
  • Guan B; College of Environmental and Resource Sciences, Zhejiang University, Hangzhou, 320058, China.
  • Jiang Y; Department of Infectious Diseases, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, 310016, China; Key Laboratory of Microbial Technology and Bioinformatics of Zhejiang Province, Hangzhou, 310016, China; Regional Medical Center for National Institute of Respiratory Diseas
Environ Pollut ; 355: 124184, 2024 Aug 15.
Article de En | MEDLINE | ID: mdl-38782162
ABSTRACT
While sodium hypochlorite (NaClO) has long been used to disinfect drinking water, concerns have risen over its use due to causing potentially hazardous byproducts. Catalytic ozonation with metal-free catalysts has attracted increasing attention to eliminate the risk of secondary pollution of byproducts in water treatment. Here, we compared the disinfection efficiency and microbial community of catalytic ozone with a type of metal-free catalyst fluorinated ceramic honeycomb (FCH) and NaClO disinfectants under laboratory- and pilot-scale conditions. Under laboratory conditions, the disinfection rate of catalytic ozonation was 3∼6-fold that of ozone when the concentration of Escherichia coli was 1 × 106 CFU/ml, and all E. coli were killed within 15 s. However, 0.65 mg/L NaClO retained E. coli after 30 min using the traditional culturable approach. The microorganism inactivation results of raw reservoir water disinfected by catalytic ozonation and ozonation within 15 s were incomparable based on the cultural method. In pilot-scale testing, catalytic ozonation inactivated all environmental bacteria within 4 min, while 0.65 mg/L NaClO could not achieve this success. Both catalytic ozonation and NaClO-disinfected methods significantly reduced the number of microorganisms but did not change the relative abundances of different species, i.e., bacteria, viruses, eukaryotes, and archaea, based on metagenomic analyses. The abundance of virulence factors (VFs) and antimicrobial resistance genes (ARGs) was detected few in catalytic ozonation, as determined by metagenomic sequencing. Some VFs or ARGs, such as virulence gene 'FAS-II' which was hosted by Mycobacterium_tuberculosis, were detected solely by the NaClO-disinfected method. The enriched genes and pathways of cataO3-disinfected methods exhibited an opposite trend, especially in human disease, compared with NaClO disinfection. These results indicated that the disinfection effect of catalytic ozone is superior to NaClO, this finding contributed to the large-scale application of catalytic ozonation with FCH in practical water treatment.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Ozone / Hypochlorite de sodium / Eau de boisson / Céramiques / Désinfection / Purification de l'eau / Désinfectants Langue: En Journal: Environ Pollut Sujet du journal: SAUDE AMBIENTAL Année: 2024 Type de document: Article Pays de publication: Royaume-Uni

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Ozone / Hypochlorite de sodium / Eau de boisson / Céramiques / Désinfection / Purification de l'eau / Désinfectants Langue: En Journal: Environ Pollut Sujet du journal: SAUDE AMBIENTAL Année: 2024 Type de document: Article Pays de publication: Royaume-Uni