Your browser doesn't support javascript.
loading
Atomically Co-dispersed nitrogen-doped carbon for sensitive electrochemical immunoassay of breast cancer biomarker CA15-3.
Han, Lei; Cai, Shuanglong; Chen, Xiaogeng.
Affiliation
  • Han L; Department of Breast Surgery, Fujian Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350001, Fujian, People's Republic of China. 572924660@qq.com.
  • Cai S; Department of Breast Surgery, Fujian Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350001, Fujian, People's Republic of China.
  • Chen X; Department of Breast Surgery, Fujian Provincial Hospital, Shengli Clinical Medical College of Fujian Medical University, Fuzhou, 350001, Fujian, People's Republic of China.
Mikrochim Acta ; 191(7): 370, 2024 06 05.
Article de En | MEDLINE | ID: mdl-38837084
ABSTRACT
The development of an ultrasensitive and precise measurement of a breast cancer biomarker (cancer antigen 15-3; CA15-3) in complex human serum is essential for the early diagnosis of cancer in groups of healthy populations and the treatment of patients. However, currently available testing technologies suffer from insufficient sensitivity toward CA15-3, which severely limits early large-scale screening of breast cancer patients. We report a versatile electrochemical immunoassay method based on atomically cobalt-dispersed nitrogen-doped carbon (Co-NC)-modified disposable screen-printed carbon electrode (SPCE) with alkaline phosphatase (ALP) and its metabolite, ascorbic acid 2-phosphate (AAP), as the electrochemical labeling and redox signaling unit for sensitive detection of low-abundance CA15-3. During electrochemical detection by differential pulse voltammetry (DPV), it was found that the Co-NC-SPCE electrode did not have a current signal response to the AAP substrate; however, it had an extremely favorable response current to ascorbic acid (AA). Based on the above principle, the target CA15-3-triggered immunoassay enriched ALP-catalyzed AAP produces a large amount of AA, resulting in a significant change in the system current signal, thereby realizing the highly sensitive detection of CA15-3. Under the optimal AAP substrate concentration and ALP catalysis time, the Co-NC-SPCE-based electrochemical immunoassay demonstrated a good DPV current for CA15-3 in the assay interval of 1.0 mU/mL to 10,000 mU/mL, with a calculated limit of detection of 0.38 mU/mL. Since Co-NC-SPCE has an excellent DPV current response to AA and employs split-type scheme, the constructed electrochemical immunoassay has the merits of high preciseness and anti-interference, and its clinical diagnostic results are comparable to those of commercial kits.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Tumeurs du sein / Carbone / Marqueurs biologiques tumoraux / Cobalt / Mucine-1 / Techniques électrochimiques / Azote Limites: Female / Humans Langue: En Journal: Mikrochim Acta / Mikrochim. Acta (1966) / Mikrochimica acta (1966) Année: 2024 Type de document: Article Pays de publication: Autriche

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Tumeurs du sein / Carbone / Marqueurs biologiques tumoraux / Cobalt / Mucine-1 / Techniques électrochimiques / Azote Limites: Female / Humans Langue: En Journal: Mikrochim Acta / Mikrochim. Acta (1966) / Mikrochimica acta (1966) Année: 2024 Type de document: Article Pays de publication: Autriche