Your browser doesn't support javascript.
loading
Gait speed in knee osteoarthritis: A simple 10-meter walk test predicts the distance covered in the 6-minute walk test.
Lozano-Meca, José; Montilla-Herrador, Joaquina; Gacto-Sánchez, Mariano.
Affiliation
  • Lozano-Meca J; Faculty of Medicine, CEIR Campus Mare Nostrum (CMN), University of Murcia, Instituto Murciano de Investigación Biosanitaria-Virgen de La Arrixaca (IMIB-Arrixaca), El Palmar, Murcia, Spain.
  • Montilla-Herrador J; Faculty of Medicine, CEIR Campus Mare Nostrum (CMN), University of Murcia, Instituto Murciano de Investigación Biosanitaria-Virgen de La Arrixaca (IMIB-Arrixaca), El Palmar, Murcia, Spain. Electronic address: montilla@um.es.
  • Gacto-Sánchez M; Faculty of Medicine, CEIR Campus Mare Nostrum (CMN), University of Murcia, Instituto Murciano de Investigación Biosanitaria-Virgen de La Arrixaca (IMIB-Arrixaca), El Palmar, Murcia, Spain.
Musculoskelet Sci Pract ; 72: 102983, 2024 08.
Article de En | MEDLINE | ID: mdl-38851178
ABSTRACT

BACKGROUND:

The 6-Minute Walk Test (6MWT) is a common performance-measure in Knee Osteoarthritis (KOA), but the pain and functional impairment characterizing the condition may interfere its adequate performance.

OBJECTIVES:

The shorter 10-m Walk Test (10mWT) could predict the distance performed on the 6MWT, therefore decreasing the burden on patients, enhancing efficiency, and reducing space- and time-constraints in clinical settings.

DESIGN:

A cross sectional study was conducted.

METHODS:

The scores from the 6MWT and the shorter 10mWT of 58 ambulatory subjects with KOA were compared. Correlation, and a univariate regression analysis to explore the predictive ability of the 10mWT, were calculated.

RESULTS:

Correlation was excellent (r = 0.913, p-value<0.001), and the predictive equation based on the 10mWT scores (R2 = 0.834, p-value<0.001) estimates the distance walked in the 6MWT with a relative error of 7.62%.

CONCLUSIONS:

The 10mWT may be an excellent assessment-tool to predict the distance walked in the 6MWT, due to its low strain on patients and as a means of improving efficiency and reducing time-constraints.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Gonarthrose / Test de marche / Vitesse de marche Limites: Aged / Female / Humans / Male / Middle aged Langue: En Journal: Musculoskelet Sci Pract Année: 2024 Type de document: Article Pays d'affiliation: Espagne Pays de publication: Pays-Bas

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Gonarthrose / Test de marche / Vitesse de marche Limites: Aged / Female / Humans / Male / Middle aged Langue: En Journal: Musculoskelet Sci Pract Année: 2024 Type de document: Article Pays d'affiliation: Espagne Pays de publication: Pays-Bas