Your browser doesn't support javascript.
loading
Highly Sensitive Detection of Hydrogen Peroxide in Cancer Tissue Based on 3D Reduced Graphene Oxide-MXene-Multi-Walled Carbon Nanotubes Electrode.
Yu, Shuai-Qun; Li, Pan; Li, Hao-Jie; Shang, Ling-Jun; Guo, Rui; Sun, Xu-Ming; Ren, Qiong-Qiong.
Affiliation
  • Yu SQ; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
  • Li P; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
  • Li HJ; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
  • Shang LJ; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
  • Guo R; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
  • Sun XM; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
  • Ren QQ; School of Medical Engineering, Xinxiang Medical University, Xinxiang 453003, China.
Biosensors (Basel) ; 14(6)2024 May 21.
Article de En | MEDLINE | ID: mdl-38920565
ABSTRACT
Hydrogen peroxide (H2O2) is a signaling molecule that has the capacity to control a variety of biological processes in organisms. Cancer cells release more H2O2 during abnormal tumor growth. There has been a considerable amount of interest in utilizing H2O2 as a biomarker for the diagnosis of cancer tissue. In this study, an electrochemical sensor for H2O2 was constructed based on 3D reduced graphene oxide (rGO), MXene (Ti3C2), and multi-walled carbon nanotubes (MWCNTs) composite. Three-dimensional (3D) rGO-Ti3C2-MWCNTs sensor showed good linearity for H2O2 in the ranges of 1-60 µM and 60 µM-9.77 mM at a working potential of -0.25 V, with sensitivities of 235.2 µA mM-1 cm-2 and 103.8 µA mM-1 cm-2, respectively, and a detection limit of 0.3 µM (S/N = 3). The sensor exhibited long-term stability, good repeatability, and outstanding immunity to interference. In addition, the modified electrode was employed to detect real-time H2O2 release from cancer cells and cancer tissue ex vivo.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Techniques de biocapteur / Nanotubes de carbone / Électrodes / Graphite / Peroxyde d'hydrogène / Tumeurs Limites: Humans Langue: En Journal: Biosensors (Basel) Année: 2024 Type de document: Article Pays d'affiliation: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Techniques de biocapteur / Nanotubes de carbone / Électrodes / Graphite / Peroxyde d'hydrogène / Tumeurs Limites: Humans Langue: En Journal: Biosensors (Basel) Année: 2024 Type de document: Article Pays d'affiliation: Chine
...