Your browser doesn't support javascript.
loading
[Design and performance study of bone trabecular scaffolds based on triply periodic minimal surface method].
Men, Yutao; Tang, Shaocan; Chen, Wei; Liu, Fulong; Zhang, Chunqiu.
Affiliation
  • Men Y; Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, P. R. China.
  • Tang S; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin 300384, P. R. China.
  • Chen W; Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, P. R. China.
  • Liu F; National Demonstration Center for Experimental Mechanical and Electrical Engineering Education, Tianjin University of Technology, Tianjin 300384, P. R. China.
  • Zhang C; Tianjin Key Laboratory for Advanced Mechatronic System Design and Intelligent Control, School of Mechanical Engineering, Tianjin University of Technology, Tianjin 300384, P. R. China.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 584-594, 2024 Jun 25.
Article de Zh | MEDLINE | ID: mdl-38932546
ABSTRACT
Triply periodic minimal surface (TPMS) is widely used because it can be used to control the shape of porous scaffolds precisely by formula. In this paper, an I-wrapped package (I-WP) type porous scaffolds were constructed. The finite element method was used to study the relationship between the wall thickness and period, the morphology and mechanical properties of the scaffolds, as well as to study the compression and fluid properties. It was found that the porosity of I-WP type scaffolds with different wall thicknesses (0.1 ~ 0.2 mm) and periods (I-WP 1 ~ I-WP 5) ranged from 68.01% ~ 96.48%, and the equivalent elastic modulus ranged from 0.655 ~ 18.602 GPa; the stress distribution of the scaffolds tended to be uniform with the increase of periods and wall thicknesses; the equivalent elastic modulus of the I-WP type scaffolds was basically unchanged after the topology optimization, and the permeability was improved by 52.3%. In conclusion, for the I-WP type scaffolds, the period parameter can be adjusted first, then the wall thickness parameter can be controlled. Topology optimization can be combined to meet the design requirements. The I-WP scaffolds constructed in this paper have good mechanical properties and meet the requirements of repairing human bone tissue, which may provide a new choice for the design of artificial bone trabecular scaffolds.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Analyse des éléments finis / Structures d'échafaudage tissulaires Limites: Humans Langue: Zh Journal: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi Sujet du journal: ENGENHARIA BIOMEDICA Année: 2024 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Analyse des éléments finis / Structures d'échafaudage tissulaires Limites: Humans Langue: Zh Journal: Sheng Wu Yi Xue Gong Cheng Xue Za Zhi Sujet du journal: ENGENHARIA BIOMEDICA Année: 2024 Type de document: Article
...