Your browser doesn't support javascript.
loading
Ultrasensitive Photoelectrochemical Biosensor for Dual-miRNAs Detection Based on Molecular Logic Gates and Methylene Blue Sensitized ZnO@CdS@Au Nanorods.
Bi, Shiliang; He, Hanxiao; Gao, Faming; Zhao, Yang.
Affiliation
  • Bi S; Hebei Key Laboratory of Nano-Biotechnology, College of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • He H; Hebei Key Laboratory of Nano-Biotechnology, College of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • Gao F; Hebei Key Laboratory of Nano-Biotechnology, College of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
  • Zhao Y; Hebei Key Laboratory of Nano-Biotechnology, College of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, China.
ACS Appl Mater Interfaces ; 16(28): 36194-36203, 2024 Jul 17.
Article de En | MEDLINE | ID: mdl-38952261
ABSTRACT
The occurrence of cancer is often closely related to multiple tumor markers, so it is important to develop multitarget detection methods. By the proper design of the input signals and logical operations of DNA logic gates, detection and diagnosis of cancer at different stages can be achieved. For example, in the early stages, specific input signals can be designed to correspond to early specific tumor markers, thereby achieving early cancer detection. In the late stage, logic gates for multitarget detection can be designed to simultaneously detect multiple biomarkers to improve diagnostic accuracy and comprehensiveness. In this work, we constructed a dual-target-triggered DNA logic gate for anchoring DNA tetrahedra, where methylene blue was embedded in the DNA tetrahedra to sensitize ZnO@CdS@Au, achieving ultrasensitive detection of the target substance. We tested the response of AND and OR logic gates to the platform. For AND logic gates, the sensing platform only responds when both miRNAs are present. In the concentration range of 10 aM to 10 nM, the photoelectric signal gradually increases with an increase of the target concentration. Subsequently, we used OR logic gates for miRNA detection. Even if only one target exists, the sensing platform exhibits excellent performance. Similarly, within the concentration range of 10 aM to 10 nM, the photoelectric signal gradually increases with an increase of the target concentration. The minimum detection limit is 1.10 aM. Whether it is the need to detect multiple targets simultaneously or only one of them, we can achieve it by selecting the appropriate logic gate. This strategy holds promising application prospects in fields such as biosensing, medical diagnosis, and environmental monitoring.
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Sulfures / Oxyde de zinc / Techniques de biocapteur / Composés du cadmium / MicroARN / Nanotubes / Techniques électrochimiques / Or / Bleu de méthylène Limites: Humans Langue: En Journal: ACS Appl Mater Interfaces Sujet du journal: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Année: 2024 Type de document: Article Pays d'affiliation: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Sulfures / Oxyde de zinc / Techniques de biocapteur / Composés du cadmium / MicroARN / Nanotubes / Techniques électrochimiques / Or / Bleu de méthylène Limites: Humans Langue: En Journal: ACS Appl Mater Interfaces Sujet du journal: BIOTECNOLOGIA / ENGENHARIA BIOMEDICA Année: 2024 Type de document: Article Pays d'affiliation: Chine
...