Your browser doesn't support javascript.
loading
Comparative evaluation of the effects of different torque settings on dentinal crack formation using single- and multi-file system: An in vitro study.
Katkam, Lavanya Rajendraprasad; Maheshwari, Zinnie; Reddy, Kranthikumar S; Gandhi, Pranita Pravin; Deore, Rahul B; Kharkar, Atharv Pramod.
Affiliation
  • Katkam LR; Department of Conservative Dentistry and Endodontics, JMF's ACPM Dental College, Dhule, Maharashtra, India.
  • Maheshwari Z; Department of Conservative Dentistry and Endodontics, JMF's ACPM Dental College, Dhule, Maharashtra, India.
  • Reddy KS; Department of Conservative Dentistry and Endodontics, JMF's ACPM Dental College, Dhule, Maharashtra, India.
  • Gandhi PP; Department of Conservative Dentistry and Endodontics, JMF's ACPM Dental College, Dhule, Maharashtra, India.
  • Deore RB; Department of Conservative Dentistry and Endodontics, JMF's ACPM Dental College, Dhule, Maharashtra, India.
  • Kharkar AP; Department of Conservative Dentistry and Endodontics, JMF's ACPM Dental College, Dhule, Maharashtra, India.
J Conserv Dent Endod ; 27(6): 603-607, 2024 Jun.
Article de En | MEDLINE | ID: mdl-38989499
ABSTRACT
Context To improve efficiency, biomechanical preparation in root canal treatment is shifting from manual SS to nickel-titanium (NiTi) rotary devices. While multi-file NiTi systems entail crack and fracture issues, modern single-file systems address these concerns.

Aims:

The aim of this study was to evaluate and compare the effects of different torque settings on dentinal crack formation using single-file systems (SFS) (One Curve [OC]) and multi-file systems (ProTaper Next [PTN]) at different levels of the tooth. Subjects and

Methods:

The study was conducted on 45 freshly extracted human mandibular premolars divided into groups OC at minimal and maximal torque, PTN at minimal and maximal torque, and a control group. After canal preparation, teeth were horizontally sectioned at 3, 6, and 9 mm from the apex, and then examined for cracks using a stereomicroscope. Statistical Analysis Used This was analyzed using Chi-square test.

Results:

PTN group Highest crack rates at the middle (55.6%) and apical (77.8%) thirds with maximum torque; OC group Highest rates at the middle (22.2%) with minimal torque and apical (11.1%) with maximum torque.

Conclusions:

Maximal torque settings had more incidence of cracks compared to minimal torque settings. It can be stated that SFS (OC) produced less cracks compared to multi-file system (PTN) at both minimal and maximal torque settings.
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: J Conserv Dent Endod Année: 2024 Type de document: Article Pays d'affiliation: Inde

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: J Conserv Dent Endod Année: 2024 Type de document: Article Pays d'affiliation: Inde