Evaluation of Dry Eye Parameters Among Electronic Cigarette Smokers.
Chew, Rui Ping; Kwan Joo Ern, Kevin; Muhammed, Julieana; Zamli, Akmal Haliza.
Affiliation
  • Chew RP; Department of Ophthalmology and Visual Science, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, MYS.
  • Kwan Joo Ern K; Department of Ophthalmology and Visual Science, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, MYS.
  • Muhammed J; Department of Ophthalmology and Visual Science, School of Medical Sciences, Universiti Sains Malaysia, Kota Bharu, MYS.
  • Zamli AH; Department of Ophthalmology, Hospital Tengku Ampuan Afzan, Kuantan, MYS.
Cureus ; 16(6): e62148, 2024 Jun.
Article de En | MEDLINE | ID: mdl-38993422
ABSTRACT
Introduction  The emergence of electronic cigarettes as the "healthier" version of smoking has been popular, especially among young adults. However, knowledge about the potential effects of e-cigarettes on ocular structures is scarce. Objective  To compare the mean change in dry eye parameters between e-cigarette smokers and non-smokers and to correlate between dry eye parameters with device power output. Methodology A cross-sectional, single-visit study was conducted involving 85 e-cigarette smokers and 85 non-smokers. All participants were evaluated on dry eye parameters, including the Ocular Surface Disease Index (OSDI) score, tear meniscus height (TMH), tear break-up time (TBUT), cornea fluorescein staining, and Schirmer's I test. The mean change in dry eye parameters was compared between e-cigarette smokers and non-smokers. The correlation between dry eye parameters with device power output was analyzed. Results Specifically, 32.94% of e-cigarette smokers were found to have a TMH <0.2 mm, compared to only 5.88% of non-smokers (p<0.001). A significant change in mean TBUT was found between the e-cigarette smokers (10.41+2.65 seconds) and non-smokers (12.66+3.14 seconds, p<0.001). The lower mean Schirmer's I test was found among e-cigarette smokers (12.75+7.24 mm, p<0.001). No significant change in the median OSDI score and corneal fluorescein staining. The OSDI score and device power output were found to have a significant positive correlation (p=0.003). There was a significant association between dry eye signs and device power output, including TMH (p=0.047), TBUT (p=0.002), Schirmer's I test (p<0.001), and corneal fluorescein staining (p<0.001). Conclusion Electronic cigarette smokers are prone to develop dry eyes. Concern should be raised on the risk of electronic cigarette use on ocular health, and regulation on e-cigarette ban should be revisited.
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: Cureus Année: 2024 Type de document: Article

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Langue: En Journal: Cureus Année: 2024 Type de document: Article