Lamina Cribrosa Configurations in Highly Myopic and Non-Highly Myopic Eyes: The Beijing Eye Study.
Han, Yingxiang; Wang, Xiaofei; Xue, Can Can; Jonas, Jost B; Wang, Ya Xing.
Affiliation
  • Han Y; Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
  • Wang X; Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
  • Xue CC; Singapore Eye Research Institute, Singapore National Eye Centre, Singapore.
  • Jonas JB; Rothschild Foundation Hospital, Institut Français de Myopie, Paris, France.
  • Wang YX; Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing, China.
Invest Ophthalmol Vis Sci ; 65(8): 28, 2024 Jul 01.
Article de En | MEDLINE | ID: mdl-39023442
ABSTRACT

Purpose:

The purpose of this study was to examine characteristics of lamina cribrosa (LC) configuration in highly myopic (HM) eyes.

Methods:

Participants from the Beijing Eye Study 2011, free of optic nerve or retinal diseases, were randomly selected to examine LC depth (LCD) and LC tilt (LCT) using three-dimensional optical coherent tomography images of the optic nerve head (ONH). LCD and LCT were measured as the distance and angle between the LC plane with two reference planes, including the Bruch's membrane opening (BMO) plane and the peripapillary sclera (PPS) plane, respectively. Each parameter was measured in both horizontal and vertical B-scans.

Results:

The study included 685 individuals (685 eyes) aged 59.6 ± 7.7 years, including 72 HM eyes and 613 non-HM eyes. LCD measurements showed no significant differences between HM eyes and non-HM eyes in both horizontal (LCD-BMO = 421.83 ± 107.86 µm for HM eyes vs. 447.24 ± 104.94 µm for non-HM eyes, P = 0.18; and LCD-PPS = 406.39 ± 127.69 µm vs. 394.00 ± 101.64 µm, P = 1.00) and vertical directions (LCD-BMO = 435.78 ± 101.29 µm vs. 450.97 ± 106.54 µm, P = 0.70; and LCD-PPS = 401.62 ± 109.9 µm vs. 379.85 ± 110.35 µm, P = 0.35). However, the LCT was significantly more negative (tilted) in HM eyes than in non-HM eyes horizontally (LCT-BMO = -4.38 ± 5.94 degrees vs. -0.04 ± 5.86 degrees, P < 0.001; and LCT-PPS = -3.16 ± 5.23 degrees vs. -0.94 ± 4.71 degrees, P = 0.003), but not vertically (P = 1.00).

Conclusions:

Although LCD did not differ significantly between HM and non-HM eyes, LCT was more negative in HM eyes, suggesting that the temporal or inferior side of the LC was closer to the reference plane. These findings provide insights into morphological and structural changes in the LC and ONH between HM and non-HM eyes.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Papille optique / Tomographie par cohérence optique / Myopie dégénérative Limites: Aged / Female / Humans / Male / Middle aged Pays/Région comme sujet: Asia Langue: En Journal: Invest Ophthalmol Vis Sci Année: 2024 Type de document: Article Pays d'affiliation: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Papille optique / Tomographie par cohérence optique / Myopie dégénérative Limites: Aged / Female / Humans / Male / Middle aged Pays/Région comme sujet: Asia Langue: En Journal: Invest Ophthalmol Vis Sci Année: 2024 Type de document: Article Pays d'affiliation: Chine