Your browser doesn't support javascript.
loading
Safety and effectiveness of using Disposable Ultrasonic shears to coagulate 5-7 mm blood vessels: protocol for a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial.
Wang, Xipeng; Li, Chengqiang; Fan, Junqiang; Hu, Jian; Wang, Mingsong; Li, Hecheng.
Affiliation
  • Wang X; Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Li C; Department of Thoracic Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Fan J; Department of Thoracic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Hu J; Department of Thoracic Surgery, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Wang M; Key Laboratory of Clinical Evaluation Technology for Medical Device of Zhejiang Province, Hangzhou, China.
  • Li H; Department of Thoracic Surgery, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
BMC Surg ; 24(1): 212, 2024 Jul 19.
Article de En | MEDLINE | ID: mdl-39030560
ABSTRACT

BACKGROUND:

The ultrasonic scalpel is widely used during surgery. It is safe and effective to close the pulmonary artery branch vessels of 7 mm or below with an ultrasonic energy device as reported. However, there have been no multicenter randomized clinical trial to assess the safety and effectiveness of using ultrasonic scalpel to coagulate 5-7 mm blood vessels in thoracic surgery.

METHODS:

This is a prospective, multicenter, randomized, parallel controlled, non-inferiority clinical trial. A total of 144 eligible patients planning to undergo lung or esophageal surgery will be randomly allocated to the experimental group and the control group. The investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) will be used in each group. The primary endpoint is the success rate of coagulating target blood vessels during surgery. Secondary endpoints include postoperative rebleeding, intraoperative bleeding volume, drainage volume, surgical duration, etc. Postoperative follow-up before and after discharge will be performed.

DISCUSSION:

This clinical trial aims to evaluate the safety and effectiveness of using the investigational product (Disposable Ultrasonic Shears manufactured by Reach Surgical, Inc.) and that of the control product (Harmonic Ace + 7, 5 mm Diameter Shears with Advanced Hemostasis) to coagulate 5-7 mm blood vessels in thoracic surgery. TRIAL REGISTRATION ClinicalTrials.gov NCT06002737. The trial was prospectively registered on 16 August 2023, https//www. CLINICALTRIALS gov/study/NCT06002737 .
Sujet(s)
Mots clés

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Matériel jetable Limites: Adult / Female / Humans / Male / Middle aged Langue: En Journal: BMC Surg Année: 2024 Type de document: Article Pays d'affiliation: Chine

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Matériel jetable Limites: Adult / Female / Humans / Male / Middle aged Langue: En Journal: BMC Surg Année: 2024 Type de document: Article Pays d'affiliation: Chine