Your browser doesn't support javascript.
loading
Comparison between 80-microns versus 100-microns flap femtosecond LASIK for correction of myopia and myopic astigmatism.
Khokhar, Sudarshan; Rani, Deeksha; Jhajharia, Hemant; Kumar, Saumya; Rathod, Aishwarya; Rajput, Sarika.
Affiliation
  • Khokhar S; Department of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Indian J Ophthalmol ; 72(9): 1308-1314, 2024 Sep 01.
Article de En | MEDLINE | ID: mdl-39185830
ABSTRACT

PURPOSE:

This study aimed to compare the safety, efficacy, and visual outcomes of 80-microns LASIK versus 100-microns LASIK in managing myopia and myopic astigmatism. The study was conducted at a tertiary care hospital in North India.

METHODS:

This was a prospective contralateral eye study that included patients with myopia and myopic astigmatism seeking refractive correction. The eligibility criteria included normal corneal topography, an epithelial thickness less than 60 microns, a calculated percentage tissue ablation (with 100-microns flap) less than 40%, a calculated residual stromal bed thickness (with 100-microns flap) more than 300 microns, and willingness to participate and follow up. Patients with glaucoma, cataracts, other visually disabling ocular pathologies, and a history of past ocular surgery were excluded. All patients underwent LASIK with 80-microns LASIK in one eye and 100-microns LASIK in the other eye. The patients were followed up for 6 months, and the results were analyzed.

RESULTS:

The study included 216 eyes of 108 patients. The mean preoperative spherical equivalent in the 80-microns group and the 100-microns group was -3.53 ± 1.81 and -3.69 ± 1.32 diopters, respectively (P = 0.78). The mean 6 months decimal postoperative UCVA was 0.98 ± 0.13 in the 80-microns group and 0.97 ± 0.14 in the 100-microns group (P = 0.99). The postoperative change in the higher-order aberration profile was comparable in both groups (P = 0.78). The percentage tissue ablation was significantly lower in the 80-microns group (P = 0.002). The incidence of flap micro striae and OBL was higher in the 80-microns group, while neither of these had any visual implications.

CONCLUSION:

The study concluded that 80-microns LASIK is an efficacious and safe alternative to 100-micron LASIK, especially useful in patients with higher myopia.
Sujet(s)

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Réfraction oculaire / Astigmatisme / Lambeaux chirurgicaux / Acuité visuelle / Topographie cornéenne / Kératomileusis in situ avec laser excimère / Lasers à excimères / Myopie Limites: Adult / Female / Humans / Male Langue: En Journal: Indian J Ophthalmol Année: 2024 Type de document: Article Pays d'affiliation: Inde Pays de publication: IN / INDIA / ÍNDIA

Texte intégral: 1 Collection: 01-internacional Base de données: MEDLINE Sujet principal: Réfraction oculaire / Astigmatisme / Lambeaux chirurgicaux / Acuité visuelle / Topographie cornéenne / Kératomileusis in situ avec laser excimère / Lasers à excimères / Myopie Limites: Adult / Female / Humans / Male Langue: En Journal: Indian J Ophthalmol Année: 2024 Type de document: Article Pays d'affiliation: Inde Pays de publication: IN / INDIA / ÍNDIA