Your browser doesn't support javascript.
loading
99mTc-HL91: "hot spot" detection of ischemic myocardium in vivo by gamma camera imaging.
Okada, R D; Johnson, G; Nguyen, K N; Liu, Z; Edwards, B; Archer, C M; North, T L; King, A C; Kelly, J D.
Affiliation
  • Okada RD; William K. Warren Medical Research Institute of the University of Oklahoma Health Sciences Center, Tulsa 74136, USA.
Circulation ; 97(25): 2557-66, 1998 Jun 30.
Article de En | MEDLINE | ID: mdl-9657477
ABSTRACT

BACKGROUND:

99mTc-HL91 is a new hypoxia imaging agent that demonstrates increased uptake and retention in globally hypoxic myocardium in vitro. The purpose of this study was to determine whether 99mTc-HL91 could detect regional ischemia in vivo by gamma camera imaging. METHODS AND

RESULTS:

Eight open-chest dogs with left circumflex (LCx) stenoses were studied. Injection of 5 mCi of 99mTc-HL91 and microspheres was followed by imaging over 4 hours. Heart slices were imaged, then stained with triphenyltetrazolium chloride (TTC), and tissues were well-counted. TTC staining demonstrated no injury. Mean LCx blood flow was 0.32+/-0.04 mL x min(-1) x g(-1), and mean left anterior descending coronary artery (LAD) flow was 0.96+/-0.02 mL x min(-1) x g(-1) (ratio, 0.33). "Hot spots" were detected in 8 of 8 experiments in vivo within 60 minutes and improved over 4 hours. Region of interest analysis of LCx/LAD activity ratios demonstrated significant increases within 30 minutes (final ratio, 3.0; P<0.05). LCx and LAD washout curves demonstrated significant differences within 15 minutes. Washout curves were biexponential over 1 hour, followed by linear retention from 1 to 4 hours. Four-hour fractional retention was 0.12 for LAD and 0.44 for LCx (P<0.01). Myocardial flow versus tracer uptake demonstrated 2 phases phase 1 (flow, 0.05 to 0.7 mL x min(-1) x g(-1)) had an inverse linear correlation (r= -0.80); phase 2, (flow, >0.7 mL x min(-1) x g(-1)) had no correlation. Ischemic heart/liver ratios remained near 1.0 for 4 hours.

CONCLUSIONS:

99mTc-HL91 positively identifies regional myocardial ischemia in a canine model using 99mTc imaging. Quantitative techniques allowed identification of ischemic myocardium within 15 minutes of tracer administration.
Sujet(s)
Recherche sur Google
Collection: 01-internacional Base de données: MEDLINE Sujet principal: Oximes / Composés organiques du technétium / Ischémie myocardique / Radiopharmaceutiques Type d'étude: Diagnostic_studies / Prognostic_studies Limites: Animals Langue: En Journal: Circulation Année: 1998 Type de document: Article Pays d'affiliation: États-Unis d'Amérique
Recherche sur Google
Collection: 01-internacional Base de données: MEDLINE Sujet principal: Oximes / Composés organiques du technétium / Ischémie myocardique / Radiopharmaceutiques Type d'étude: Diagnostic_studies / Prognostic_studies Limites: Animals Langue: En Journal: Circulation Année: 1998 Type de document: Article Pays d'affiliation: États-Unis d'Amérique