Comparison between precipitin and ELISA tests in the bloodmeal detection of Aedes aegypti (Linnaeus) and Aedes fluviatilis (Lutz) mosquitoes experimentally fed on feline, canine and human hosts.
Mem Inst Oswaldo Cruz
; 96(5): 693-5, 2001 Jul.
Article
in En
| MEDLINE
| ID: mdl-11500773
ABSTRACT
The identification of arthropod bloodmeals is important in many epidemiological studies, as, the understanding of the life cycle of vectors and the pathogens they transmit, as well as helping to define arthropods' control strategies. The precipitin test has been used for decades, but ELISA is slowly becoming more popular. To compare the two tests for sensitivity, specificity and accuracy to detect small insect bloodmeals, Aedes aegypti or Ae. fluviatilis mosquitoes were fed either on feline, canine or human hosts. Mosquitoes were frozen at 6, 12, 24, 48 or 72 h after feeding. Precipitin test showed better specificity and accuracy and ELISA test showed higher sensitivity. Better results with both tests were achieved when mosquitoes were frozen within 48 h from feeding.