Your browser doesn't support javascript.
loading
Potential for radiation therapy technology innovations to permit dose escalation for non-small-cell lung cancer.
Manon, Rafael R; Jaradat, Hazim; Patel, Rakesh; Zhang, Tiezhi; Fenwick, John; Tome, Wolfgang; Fowler, Jack; Paliwal, Bhudatt; Soisson, Emilie; Yuan, Zhilong; Mehta, Minesh.
Affiliation
  • Manon RR; Department of Radiation Oncology, M. D. Anderson Cancer Center-Orlando, FL, USA.
Clin Lung Cancer ; 7(2): 107-13, 2005 Sep.
Article in En | MEDLINE | ID: mdl-16179097
ABSTRACT

BACKGROUND:

Innovations in radiation therapy (RT) technology could have the potential to allow for radiation dose escalation by evaluating tumor motion, minimizing and compensating for motion, and evaluating delivery technologies such as 3-dimensional (3D) conformal radiation therapy (CRT) and intensity-modulated RT (IMRT) using tomotherapy. MATERIALS AND

METHODS:

Ninety different RT plans were generated using 3 different treatment techniques for 10 patients. These were evaluated using dosimetric tools such as dose-volume histogram (DVH) analysis, tumor equivalent uniform dose (EUD), and dosimetric parameters predictive for lung toxicity, such as the volume of lung receiving > 20 Gy of radiation (V20) and the normalized mean total radiation dose to the lung (NTDmean). The 3 techniques studied included free breathing using 3D CRT, 3D CRT with maximum-inspiration breath-hold (MIBH) to minimize tumor motion, and IMRT delivery with MIBH; the combination of 3 separate planning treatment-volume sets resulted in the generation of 90 different treatment plans. To plan these, patients underwent treatment-planning computed tomography in MIBH and free breathing followed by simulation with measurement of tumor motion and generation/evaluation of DVHs, EUDs, V20, and NTDmean.

RESULTS:

Average tumor motion was 1.54 cm in the cephalocaudad directions, 1.26 cm in the anteroposterior directions, and 0.56 cm in the lateral directions between maximum inspiration and expiration. Maximum-inspiration breath-hold produced superior lung sparing evidenced by lower V20 and NTDmean values, and these parameters predicted lower modeled pneumonitis rates. Tomotherapy-based IMRT provided further lung sparing.

CONCLUSION:

Treatment in MIBH results in lower V20 and NTDmean values and lower modeled pneumonitis rates. This effect is enhanced by the use of IMRT. The use of MIBH with IMRT may therefore aid in escalating the dose in RT.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Non-Small-Cell Lung / Radiotherapy, Conformal / Lung Neoplasms Type of study: Evaluation_studies / Prognostic_studies Limits: Humans Language: En Journal: Clin Lung Cancer Journal subject: NEOPLASIAS Year: 2005 Document type: Article Affiliation country: Publication country: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Non-Small-Cell Lung / Radiotherapy, Conformal / Lung Neoplasms Type of study: Evaluation_studies / Prognostic_studies Limits: Humans Language: En Journal: Clin Lung Cancer Journal subject: NEOPLASIAS Year: 2005 Document type: Article Affiliation country: Publication country: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA