ABSTRACT

BACKGROUND:

Wear debris has been implicated in the pathogenesis of osteolysis. Alumina-on-alumina ceramic bearings have a low wear rate, which may reduce the prevalence of osteolysis. The purpose of this study was to determine the rates of wear and osteolysis associated with modern cementless hip arthroplasty with alumina-on-alumina bearings at five years.

METHODS:

We analyzed a series of 301 third-generation alumina-on-alumina cementless primary total hip replacements in 283 patients. The average age of the patients at the time of the arthroplasty was fifty-eight years. All procedures were performed with use of the same surgical technique and the same implant at a single center. At a minimum of five years postoperatively, ten patients had died and twenty-two patients were lost to follow-up. We assessed patients clinically and radiographically, and all retrieved bearings were analyzed for wear.

RESULTS:

At the time of the latest follow-up, the mean Harris hip score was 95 points. All surviving implants had radiographic evidence of stable bone ingrowth. There were nine revisions of one or both components. Four stems were revised following periprosthetic fracture, one stem was revised because of aseptic loosening at two months, and one stem was revised to facilitate a femoral shortening osteotomy. Two cups were revised because of psoas tendinitis, and both components of one arthroplasty were revised because of impingement and osteolysis. The rate of survival of both components, with revision because of aseptic loosening or osteolysis as the end point, was 99% at seven years. The retrieved femoral heads showed an early median wear rate of 0.2 mm(3) per year.

CONCLUSIONS:

Cementless primary total hip prostheses with a third-generation alumina-on-alumina bearing showed very low wear and were associated with minimal osteolysis at the time of follow-up, at a minimum of five years.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Osteolysis / Prosthesis Design / Arthroplasty, Replacement, Hip Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Bone Joint Surg Am Year: 2007 Document type: Article Affiliation country:
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Osteolysis / Prosthesis Design / Arthroplasty, Replacement, Hip Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Bone Joint Surg Am Year: 2007 Document type: Article Affiliation country: