[High-performance liquid chromatography-mass spectrometry for determining olmesartan in human plasma].
Chen, Shi-Heng; Wu, Cui-Fang; Chen, Ben-Mei; Pei, Qi; Tan, Hong-Yi; Yang, Li; Yang, Guo-Ping.
Affiliation
  • Chen SH; Department of Pharmacy, Liling Hospital of Traditional Chinese Medicine, Liling 420000, China.
Nan Fang Yi Ke Da Xue Xue Bao ; 28(6): 1104-5, 2008 Jun.
Article in Zh | MEDLINE | ID: mdl-18583274
ABSTRACT

OBJECTIVE:

To establish a simple and rapid HPLC-MS method for determining the contents of olmesartan in human plasma.

METHODS:

Plasma were precipitated with trifluoroacetic acid, then analyzed on an HyPurity C(18) column (150 mm 2.1 mm, 5 microm). Samples at 40 degrees celsius;. The mobile phase consisted of water-methanol- acetonitrile(146026) with a flow rate of 0.22 ml/min.

RESULTS:

The lower limit of qualification was 25 microg/L. The calibration curve was linear over the range of 25-3200 microg/L (r=0.9998), with the intra-day and inter-day RSD less than 15%.

CONCLUSION:

The method is sensitive, rapid and suitable for the study of pharmacokinetics and bioavailability of olmesartan.